Baldor ID101F50-E manual Appendix a Parameters, Parameter List

Page 72

Appendix A

Parameters

Parameter List

Param Parameter Description No.

Adj.

Range

Factory Setting

User

Setting

02

Software revision

View only

View only

 

03

Rated current

View only

View only

 

07

Last fault

View only

View only

 

08

Second fault

View only

View only

 

09

First fault

View only

View only

 

12

Output frequency

View only

View only

 

13

Output voltage

View only

View only

 

14

Output current

View only

View only

 

15

Drive load

View only

View only

 

16

Load torque

View only

View only

 

17

Heatsink temperature

View only

View only

 

21

Operating mode

0-11

0

 

24

Analog command select

0-3

0

 

31

Min. output frequency

0.1-400Hz

0Hz

 

32

Max. output frequency

20-400Hz

60Hz

 

33

Preset speed #1

0.1-400Hz

5Hz

 

34

Preset speed #2

0.1-400Hz

20Hz

 

35

Preset speed #3

0.1-400Hz

40Hz

 

36

Preset speed #4

0.1-400Hz

60Hz

 

37

Preset speed #5

0.1-400Hz

0Hz

 

38

Preset speed #6

0.1-400Hz

0Hz

 

39

Minimum frequency

0.1-400Hz

10Hz

 

 

torque limit

 

 

 

41

Accel/Decel/Coast select

0-7

0

 

42

Accel Time #1

.1-600sec

3sec

 

43

Decel Time #1

.1-600sec

3sec

 

44

Accel Time #2

.1-600sec

1sec

 

45

Decel Time #2

.1-600sec

1sec

 

46

Decel Time Torque limit

.1-30sec

1sec

 

Level 2 parameters are shaded.

Parameters A-1

Image 72
Contents Series Inverter Control Installation and Operating Manual MN710Table of Contents Level One Parameter Adjustments Min Output Frequency Appendix a Limited Warranty Section General InformationSafety Notice General Information Specifications NemaElectronic Potentiometer Fault Conditions Operator KeypadAnalog Outputs Relay OutputsRatings Catalog No Input OutputAmps Volts General Information Section Installation Location and MountingTerminal Access Cover Removal Wiring Considerations Terminal and Jumper LocationsInstallation Wire Size and Protection Devices Breaker Fast Time AWG Cu Acting DelayRated Input Input Fuses Catalog No Main Circuit Wiring AC Power Connections Motor Connections Contactor Typical Connections for M-ContactorLogic Wiring Analog Command InputsAnalog Output Opto Isolated InputsExternal Trip Connection Jumper J19 Input Selection Jumper J19 SelectionsSelection Of Operation Mode And Connection Diagrams Wire Run/Stop Connections Speed SelectFunction PS2 PS1 Ramp SelectParameter 21 Operating Mode = 4 or Wire Run/Stop, Electronic Potentiometer Connections Parameter 21 Operating Mode =MOL Terminal Connections 77-External Trip Select Analog MeterRelay Output Installation Pre-Operation Checks Check of Electrical ItemsCheck of Motors/Couplings Temporary Application of Power Pre-Operation Check ListInstallation Section Operation Keypad Key FunctionsOperation Keypad Status Indicator Status Indication Operating ConditionDescription of Keypad Displays Symbol Description Stop ModeRun Mode Control Operation Adjustment Program ModeSecurity Access/Lockout Level One Parameter Adjustments Parameter 21-Operating Mode Value Start Control Type of ControlCommand Control Terminals Description FWD REV PS1 PS2 Operation Operation Parameter 71-ANALOG Output Select Level Two Parameter Adjustments Parameter 75-RELAY Output Select Value DescriptionOperation Operation Parameter 41-ACCEL/DECEL/COAST Select Value Description Operation Braking Action / Function DC Braking Disabled Parameter 41-Parameter 47-DC Brake TimeVolts/Hertz Profiles Linear50% Square LawOperation Operation Parameter 77-External Trip Select Description / FunctionParameter 81-Factory Settings Value Description Parameter 82-Start Options Value Description Command is given at the Control Terminal Strip Operation Section Troubleshooting Diagnostic DisplaysFault Codes Fault Code Description Maintenance TroubleshootingIndication Possible Cause Corrective Action Motor overloadedAdjusted SpeedsOverload Input voltage too high Troubleshooting Illustrations Illustrations HP Nema 230 & 460VAC Illustrations Appendix a Parameters Parameter ListParam Parameter Description Adj Factory User Range Setting Parameter List ±Box Fort Smith, AR 72902±2400 501 646±4711 Fax 501 648±5792 Form 1099A Baldor Electric Company MN710 98 C&J2500

ID101F50-E specifications

The Baldor ID101F50-E is an advanced industrial electric motor designed for a variety of heavy-duty applications. Known for its robust construction and high efficiency, this motor is a preferred choice in manufacturing, conveyor systems, and automated machinery where reliability and performance are critical.

One of the primary features of the ID101F50-E is its outstanding efficiency rating. With high efficiency levels, it helps reduce energy consumption, which not only lowers operating costs but also aligns with modern demands for sustainability in industrial practices. The motor's efficiency contributes to a reduced carbon footprint, making it a more environmentally friendly option.

Another significant characteristic of the Baldor ID101F50-E is its high power output. This motor can deliver substantial torque, making it suitable for applications requiring heavy lifting and durable operation. Its design allows for continuous operation at high loads without overheating, which is essential for industries that rely on uninterrupted functionality.

In terms of construction, the ID101F50-E is built with high-quality materials that ensure durability and longevity. The robust housing and premium internal components assist in protecting the motor from harsh environmental conditions, making it well-suited for demanding industrial environments. Its rugged construction means it can withstand vibration, extreme temperatures, and exposure to contaminants.

The motor also incorporates advanced technologies that enhance its performance. For instance, it employs precision engineering techniques in its rotor and stator designs, which minimize losses during operation. This contributes to its overall high performance and reliability. Additionally, the ID101F50-E features advanced cooling mechanisms to maintain optimal operating temperatures, ensuring stability and longevity.

Further enhancing its usability, the Baldor ID101F50-E is designed for easy installation and maintenance. Its standard mounting configurations allow for straightforward integration into existing systems. Maintenance access is simplified, which reduces downtime and helps keep production schedules on track.

In conclusion, the Baldor ID101F50-E is a powerful electric motor that strikes an excellent balance between performance, efficiency, and durability. Its high efficiency, significant power output, robust construction, and advanced technologies make it an ideal choice for various industrial applications, standing as a testament to Baldor's commitment to innovation and quality in electric motor design.