7.PROBLEM CHECKLIST
The machine you have chosen is of the highest quality. Correctly stored away from frost it should operate without problems. If a problem does arise, please check the following chart as a solution may be at hand.
PROBLEM | POSSIBLE CAUSE | CORRECTION |
Machine refuses | Plug not connected | Connect plug |
to start | Defective socket | Try another socket |
| Fuse blown | Change the fuse |
| Defective extension cable | Try without extension cable |
| Wrong mains voltage | Check mains voltage corresponds |
|
| to specifications of machine |
|
|
|
Pump stops | Fuse blown | Change fuse and check size of |
|
| extension cable |
| Overheating due to poor | Check inlet water flow rate - hose |
| water Supply | should fill a 10 litre bucket in one |
|
| minute |
|
| |
Strong pressure Nozzle partly blocked | Clean dirt from nozzle hole with | |
fluctuations |
| needle and rinse from the front |
| Inadequate mains water | Check inlet water flow rate |
|
|
|
Machine does | Nozzle blocked/worn out | Clean/replace nozzle |
not reach | Inadequate mains water | Check inlet water flow rate |
operating | Inlet hose squeezed | Straighten out hose |
pressure | Water filter clogged (3.1 | Clean filter |
| item15) |
|
| Inlet hose blocked | Check hose for leaks or blockages |
|
|
|
No detergent | Wrong pressure | Set Spray Lance at the minimum |
suction |
| working pressure |
| Blocked filter in | Unblock filter |
| detergent tank | Clean ventilation hole in cover of |
|
| Detergent Tank |
|
|
|
In the unlikely event that you need to return your machine to your supplier,
please ensure that this is returned, complete with hose, gun and all accessories.
Note: Inrush currents cause