Code

Problem

Check

 

 

 

17

Over speed fault

Motor RPM exceeded 110% of programmed MAX Motor speed.

 

 

Type PRINT MAXMOTORSPEED. If the value returned exceeds

 

 

the maximum mechanical speed of the motor specified in the

 

 

catalog, type MAXMOTORSPEED = xxxx where xxxx is the

 

 

maximum speed listed in the catalog, in RPM.

 

 

You should retune the motor after changing this parameter.

 

 

Check the Mint demanded velocity by using either the QuickWatch

 

 

tab or Capture tab and compare with the MAXMOTORSPEED

 

 

parameter. If the Mint demanded velocity is greater than the

 

 

maximum speed of the motor, modify your Mint program to

 

 

generate a slower demand velocity.

 

 

 

19

Control temp fault

Temperature of drive heatsink exceeded safe level.

 

 

Check correct operation of fans (if fitted) and ensure that they are

 

 

clear of dirt.

 

 

Check the ambient temperature around the drive.

 

 

Ensure that the unit is adequately ventilated.

 

 

If the problem persists add additional cooling.

 

 

 

21

Lost User Data

Battery backed RAM parameters have been lost or corrupted.

 

 

If the fault did not clear automatically after power-up, enter the

 

 

“Drive Setup” dialog and retune the MintDrive by following the

 

 

tuning setup (see section 4.2 on page 51).

 

 

 

22

Microprocessor

Turn off the power supply and wait for the residual Bus voltage to

 

reset

reach 0VDC before turning on.

 

 

Power-cycle the MintDrive. Check power-supply

 

 

 

26

New Base Id fault

Control board was changed since last operation.

 

 

Power-cycle the MintDrive.

 

 

 

31

Feedback module

Indicates a problem with the feedback device.

 

fault

If the problem persists after you have power-cycled the MintDrive

 

 

 

 

and you are using an encoder, rotate the motor shaft and

 

 

power-cycle the MintDrive again

 

 

 

32

Serial watchdog fault

Inter-processor communication problem.

 

 

Abort any program that may be running by pressing CTRL+E.

 

 

Type CANCEL. If the fault re-appears, power-cycle the MintDrive.

 

 

 

93

Page 105
Image 105
Baldor MN1274 06/2001 installation manual Code Problem Check