CAUTION:

To prevent equipment damage, be certain that the input power has correctly sized protective

 

devices installed.

 

CAUTION:

To prevent equipment damage, be certain that input and output signals are powered and

 

referenced correctly.

CAUTION:

To ensure reliable performance of this equipment be certain that all signals to/from the drive

 

are shielded correctly.

CAUTION:

Suitable for use on a circuit capable of delivering not more than the RMS symmetrical short

 

circuit amperes listed here at rated voltage.

 

Horsepower

RMS Symmetrical Amperes

 

1-50

5,000

CAUTION:

Avoid locating the drive immediately above or beside heat generating equipment, or directly

 

below water or steam pipes.

CAUTION:

Avoid locating the drive in the vicinity of corrosive substances or vapors, metal particles and

 

dust.

 

CAUTION:

Do not connect AC power to the drive terminals U, V and W. Connecting AC power to these

 

terminals may result in damage to the drive.

CAUTION:

Baldor does not recommend using “Grounded Leg Delta” transformer power leads that may

 

create ground loops and degrade system performance. Instead, we recommend using a four

 

wire Wye.

 

CAUTION:

Drives are intended to be connected to a permanent main power source, not a portable

 

power source. Suitable fusing and circuit protection devices are required.

CAUTION:

The safe integration of the drive into a machine system is the responsibility of the machine

 

designer. Be sure to comply with the local safety requirements at the place where the

 

machine is to be used. In Europe these are the Machinery Directive, the ElectroMagnetic

 

Compatibility Directive and the Low Voltage Directive. In the United States this is the National

 

Electrical code and local codes.

CAUTION:

Drives must be installed inside an electrical cabinet that provides environmental control and

 

protection. Installation information for the drive is provided in this manual. Motors and

 

controlling devices that connect to the drive should have specifications compatible to the

 

drive.

 

CAUTION:

Violent jamming (stopping) of the motor shaft during operation may damage the motor and

 

drive.

 

CAUTION:

Do not tin (solder) exposed wires. Solder contracts over time and may cause loose

 

connections. Use crimp connections where possible.

CAUTION:

Electrical components can be damaged by static electricity. Use ESD (electro-static

 

discharge) procedures when handling this drive.