2.4Motor connections

This section provides instructions for connecting the motor.

Location

Connector X1, single or 2-part connector

 

 

 

Part number

MD1A...

MD2A...

 

 

 

Nominal output voltage

160VDC

320VDC

 

 

 

Range

135-176VDC

306-350VDC

 

 

 

 

 

 

 

 

 

 

 

 

(MintDrive 2.5A / 5A / 7.5A

 

 

 

 

 

 

 

 

 

X1 connector shown)

PE

 

 

 

 

 

 

U

 

U

 

 

M

 

V

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

W

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional

 

 

 

 

 

motor circuit

 

 

 

 

 

contactors

 

 

 

CAUTION: Do not connect power to the MintDrive UVW outputs. The MintDrive might be damaged.

CAUTION: The motor leads U, V and W must be connected to their corresponding U, V or W terminal on the motor. Mis-connection will result in uncontrolled motor movement.

All cables must be shielded. The maximum allowable cable length is 82ft (25m).

Note: For CE compliance the MintDrive and motor earth should be connected to the enclosure backplane. (The enclosure backplane should be connected to the earth at the mains source. There should be a separate connection from the earth at the mains source to the plant ground rod).

19

Page 31
Image 31
Baldor MN1274 06/2001 installation manual Motor connections, Nominal output voltage