7.1.3 Power up

7.1.3 Power up

Problem

Check

 

 

No LEDs are illuminated

Check that the 24VDC power supply is connected on connector X1

 

and is switched on.

 

Check the mains supply is connected and switched on.

 

 

One or more of the Monitor,

Check power connections. Power-cycle the MintDrive.

Ready or CAN LEDs is not

 

illuminated

If the problem persists contact Baldor Technical Support.

 

 

The ’Ready’ LED is red.

The drive has detected an error.

 

Type PRINT DRIVEFAULT in the Terminal window or click the error

 

button on the motion toolbar to find the error code(s).

 

See section 7.1.6 on page 91.

 

 

A CAN LED is red or flashing

See section 7.1.7 on page 94.

red.

 

 

 

The Ready LED is green and

The drive has powered-up into ’Local’ mode.

the Monitor LED indicates ‘L’

Power-cycle the MintDrive.

 

If the problem persists then contact Baldor Technical Support.

 

 

The Ready LED is green and

The MintDrive has detected a motion error.

the Monitor LED indicates ‘E’

Type PRINT AXISERROR at the command line or click on the error

 

button on the motion toolbar to find the error code(s).

 

Click the Clear Motion Errors button on the motion toolbar.

 

 

The message Variables

Type RELEASE in the Terminal window to clear variables from the

corrupted. Use RELEASE.

variable stack.

is shown at power-up.

If the problem persists then this indicates a battery problem.

 

 

Trickle charge the MintDrive’s battery by leaving the unit powered

 

for 24~48 hours.

 

If the problem still persists contact Baldor Technical Support.

 

 

The message Memory

Type NEW at the Configuration prompt (type CON to display C>).

Corruption. Use NEW to

Type NEW at the Program prompt (type PROG to display P>).

clear buffers. is shown at

This will clear the corrupted programs from memory.

power-up.

If the problem persists then this indicates a battery problem.

 

 

Trickle charge the MintDrive’s battery by leaving the unit powered

 

for 24~48 hours.

 

If the problem still persists contact Baldor Technical Support.

 

 