3.3.2Digital Inputs - X5

3.3.2Digital Inputs - X5

 

 

Location Connector X5

 

 

 

Pin

Name

Mint keyword

 

 

1

DIN0

IN.0

 

 

2

DIN2

IN.2

 

 

3

DIN4

IN.4

 

 

4

DIN6

IN.6

 

 

5

DIN8

IN.8

1

 

14

DIN1

IN.1

14

15

DIN3

 

 

IN.3

 

 

 

 

16

DIN5

IN.5

 

 

17

DIN7

IN.7

13

25

18

DIN9

IN.9

Description Ten general purpose optically isolated AC digital inputs

 

 

 

 

 

(DIN0 to DIN9).

 

The digital inputs DIN0 - DIN9 can be read individually using the associated Mint IN keyword (for example IN.0) and can be configured for any number of user definable functions. These inputs are sampled every servo loop (0.5ms to 2ms).

External +24VDC supply

Active high: A=+24VDC B=0V

Active low:

A=0V

 

B=+24VDC

A

B

X5

1DIN0 (IN.0)

2DIN2 (IN.2)

3DIN4 (IN.4)

4DIN6 (IN.6)

5DIN8 (IN.8)

6COM

14DIN1 (IN.1)

15DIN3 (IN.3)

16DIN5 (IN.5)

17DIN7 (IN.7)

18DIN9 (IN.9)

Figure 17 - X5 Digital inputs