D.1.3 EMC mains filters

AC filters remove high frequency noise from the mains supply, protecting the MintDrive. These filters also prevent high frequency signals from being transmitted back onto the power lines and help meet CE requirements. To select the correct filter, see section 2.3.10.

D.1.3.1 Catalog numbers

Schaffner

Rated volts

Rated

Leakage

Weight

Baldor catalog

amps

filter type

current (mA)

lbs (kg)

number

 

@ 40°C

 

 

 

 

 

 

 

 

 

 

 

FN 2070-6-06

250

6

0.4

0.99 (0.45)

ASR30545

FN 2070-10-06

250

10

0.4

1.61 (0.73)

FN2070-10-06

FN 2070-12-06

250

12

0.4

1.61 (0.73)

ASR30548

FN 351-36-33

440

36

28.0

6.61 (3.0)

ASR24670

FN 351-50-33

440

50

29.6

6.83 (3.1)

ASR24671

D.1.3.2 Filter dimensions - FN351-36-33 and FN351-50-33

4.53 (115)

F = Depth

G

 

 

G

 

D

C

E

 

H

 

 

M6

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

Dimension

Dimensions inches (mm)

 

A

9.84 (250)

 

B

7.87 (200)

 

C

5.9 (150)

 

D

4.72 (120)

 

E

5.35 (136)

 

F

2.55 (65)

 

G

0.78 (20)

 

H

0.83 (21)

137