3.2.4Analog Outputs, Bipolar - X11

 

 

 

Location

Connector X11

 

 

 

 

 

 

 

 

 

 

Pins

6

7

 

 

 

 

 

 

 

 

 

Name

AOUT2

AOUT3

 

 

 

 

 

 

 

 

 

Mint keyword

AUXDAC.2

AUXDAC.3

6

 

 

 

 

 

Description

Two independent assignable outputs.

 

 

7

 

 

 

 

 

Output range: ±10VDC.

 

 

 

 

 

 

 

 

 

Resolution: 8-bit with sign.

 

 

 

 

 

Output current: 1mA maximum.

 

 

 

 

Update interval: 2ms.

 

 

 

 

 

 

 

Two programmable analog outputs that can be used to provide real time status of various control conditions. The voltage from the output buffer is supplied through a 50Ω resistor for short circuit protection.

GND

Output 2

Output 3

X11

1

6

7

AOUT2 (AUXDAC.2)

AOUT3 (AUXDAC.3)

Figure 13 - AOUT2 and AOUT3 analog outputs

CAUTION: Following power-up or a system reset, both outputs will initially be set at approximately +10V. This condition will remain, for a short period, during the software initialization process. For this reason, care should be taken if this output is being used as a drive reference for a speed controller.