Baldor MN1274 06/2001 MintDrive, Circuit breaker and fuse, single phase, package size C

Models: MN1274 06/2001

1 154
Download 154 pages 13.87 Kb
Page 25
Image 25
Figure 5 - Circuit breaker and fuse, single phase, package size C

L

N

 

 

Circuit

 

 

Earth

 

 

 

Breaker

 

 

 

L1

L2

L3

PE

 

MintDrive

 

L N

Fuse

Connection

L1 L2

Circuit breaker and fuse not supplied. For CE Compliance, see Appendix C.

Figure 5 - Circuit breaker and fuse, single phase, package size C

L1

L2

L3

 

Circuit

 

 

Earth

 

 

 

Breaker

 

 

 

L1

L2

L3

PE

 

MintDrive

 

L1 L2 L3

Fuse

Connection

L1 L2 L3

Circuit breaker and fuse not supplied. For CE Compliance, see Appendix C.

Figure 6 - Circuit breaker and fuse, three phase, package size C

Note: Metal conduit or shielded cable should be used. Connect conduits so the use of a Reactor or RC Device does not interrupt EMI/RFI shielding. If local codes do not specify different regulations, use the same gauge wire for Earth ground as is used for L and N.

Connect earth to the backplane of the enclosure.

13