Baldor MN1274 06/2001 installation manual Single phase connection to package size A or B, E L N

Models: MN1274 06/2001

1 154
Download 154 pages 13.87 Kb
Page 27
Image 27
2.3.5Single phase connection to package size A or B

2.3.5Single phase connection to package size A or B

E

L

N

Note:

Location

Connector X1, single or 2-part connector

 

 

 

Part number

MD1A...

MD2A...

 

 

 

Input voltage

115VAC, 1φ line to neutral

230VAC, 1φ line to neutral

 

 

 

Range

97-125VAC

220-250VAC

 

 

 

For single phase connection, the voltage ripple on the DC-bus is 25Vp-p for 5A (the peak current for a 2.5A MintDrive) and 50Vp-p for 10A (the peak current for a 5A MintDrive). This can limit the maximum speed of the motor.

Tightening torque for terminal block connections is 4.4~5.3 lbin (0.5~0.6Nm).

The threaded holes in the top and bottom of the enclosure are for cable clamps (provided). The holes are threaded for M4 bolts no longer than 0.47” (12mm) in length. Longer bolts may short circuit the electrical components inside the MintDrive.

2.3.6Single phase connection to package size C

or

Earth stud

 

 

E

 

 

Location

Connector X1, single or 2-part connector

 

 

 

 

 

L

 

 

Part number

MD1A...

MD2A...

 

 

 

 

 

 

 

Input voltage

115VAC, 1φ line to neutral

230VAC, 1φ line to neutral

N

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

97-125VAC

220-250VAC

 

 

 

 

 

 

Note: For single phase connection, the voltage ripple on the DC-bus is 25Vp-p for 5A (the peak current for a 2.5A MintDrive) and 50Vp-p for 10A (the peak current for a 5A MintDrive). This can limit the maximum speed of the motor.

Tightening torque for terminal block connections is 4.4~5.3 lbin (0.5~0.6Nm).

The threaded holes in the top and bottom of the enclosure are for cable clamps (provided). The holes are threaded for M4 bolts no longer than 0.47” (12mm) in length. Longer bolts may short circuit the electrical components inside the MintDrive.

15

Page 27
Image 27
Baldor MN1274 06/2001 Single phase connection to package size A or B, Single phase connection to package size C, E L N