2.5.2Encoder option

The encoder connections are made using the 15-pin D-type female connector X2. This provides the ABZ channels and Hall signals. Twisted pair cables must be used for the complementary signal pairs e.g. CHA+ and CHA-. The overall cable screen/shield must be connected to the metallic shell of the D-type connector.

 

 

Location Connector X2, 15-pin D-type female connector

 

 

Pin

Encoder function

 

 

1

CHA+

 

 

2

CHB+

 

 

3

CHZ+

 

 

4

Hall U+

 

 

5

Hall U-

10

 

6

CHA-

 

7

CHB-

15

5

8

CHZ-

 

 

11

1

9

Hall W+

6

 

10

Hall V+

 

 

11

+5V

 

 

12

(not connected)

 

 

13

DGND

 

 

14

Hall W-

 

 

15

Hall V-

Encoder

Hall

Feedback

Twisted pairs

Connector backshell

X2

1CHA+

6CHA-

2CHB+

7CHB-

3CHZ+ (INDEX)

8CHZ- (INDEX)

11 +5V

13 DGND

4Hall U+

5Hall U-

9Hall W+

14 Hall W-

10 Hall V+

15 Hall V-

12 Not Used

Figure 9 - Encoder cable connections