Baldor MN1274 06/2001 MintDrive indicators, Monitor LED display, CAN 1 and 2 LEDs, Ready LED

Models: MN1274 06/2001

1 154
Download 154 pages 13.87 Kb
Page 15
Image 15
1.3MintDrive indicators

1.3MintDrive indicators

1.3.1Monitor LED display

The 7-segment Monitor LED display indicates general MintDrive status information:

 

Drive Disabled

 

Drive in error (see section 7)

 

 

 

 

 

Drive Enabled

 

Follow mode

 

 

 

 

 

Jogging

 

Local (see troubleshooting guide)

 

 

 

 

 

Positional Move i.e. MOVEA, MOVER

 

Flying shear

 

 

 

 

 

Homing

 

Cam

 

 

 

 

 

Incremental move i.e. INCA, INCR

 

Speed Demand

 

 

 

 

 

Torque mode

 

Firmware being updated by WorkBench

 

 

 

 

1.3.2 CAN 1 and 2 LEDs

The CAN 1 and 2 LEDs refer to the independent CAN buses CAN1 and CAN2.

Green

The bus is operational

 

 

Red/

The bus is passive (see page 94)

Green

 

Red

The bus is OFF (see page 94)

 

 

Off

No primary power to the MintDrive

 

 

1.3.3 Ready LED

The front panel Ready LED indicates the general status of the MintDrive.

Green

The MintDrive is operating normally

 

 

Red

An error condition exists (see page 91)

 

 

Off

No primary power to the MintDrive

 

 

1.3.4DB On (Regeneration Load) LED

The front panel DB On LED indicates regeneration activity.

 

Yellow

Power is being dissipated into the regeneration resistor

 

 

 

 

Off

No regeneration occurring

 

 

 

 

 

 

3

Page 15
Image 15
Baldor MN1274 06/2001 MintDrive indicators, Monitor LED display, CAN 1 and 2 LEDs, Ready LED, DB On Regeneration Load LED