Baldor MN1274 06/2001 installation manual Important Note

Models: MN1274 06/2001

1 154
Download 154 pages 13.87 Kb
Page 65
Image 65
Important Note:

6.Click Next > .

The Axis Configuration Test Select frame provides two options. Click PERFORM AXES CONFIGURATION TESTS.

The axis configuration tests allows MCT to tune the MintDrive for use with the attached motor.

7.Using the drop-down boxes, select the exact motor type. This information can be found stamped into the label attached to the motor.

Important Note:

The following axis configuration tests must be performed with the motor mechanically disconnected from other machinery. The tests will cause movement of the motor, so ensure that it is safe for the motor to operate.

If it is safe for the motor to rotate, click Coarse Tune Motor Parameters .

Click OK to confirm that you wish to begin the tests. MCT will begin the motor tests.

8.For the final test, the load should be connected to the motor.

Ensure that it is safe for the motor to operate when connected to the load. If it is safe for the motor to operate, click OK. MCT will perform the final test.

9.Click Next > to continue with the tuning process.

Note: If an error occurs during any of the tests, an error number will appear on the error button at the top of the window: Manual background

Click the button to see details of the error. When you have fixed the error, click Clear Errors and then Coarse Tune Motor Parameters to restart the tests.