2.5Feedback connections

2.5Feedback connections

Two feedback options are available; a commutating encoder or a resolver, both using connector X2. Check with the catalog number (see page 2) to ensure you are wiring the correct feedback device.

Resolver based MintDrives provide a simulated encoder output signal available on connector X3 for master/slave type applications. Encoder based MintDrives duplicate the encoder signals entering X2.

The following points must be observed when wiring the feedback device:

HThe feedback device wiring must be separated from power wiring

HParallel runs of the device wiring must be separated from power cables by at least 3” (76mm) H Power wires must be crossed at right angles only

H To prevent contact with other conductors or grounds, ungrounded ends of shields must be insulated.