Delta DTT2450 HOW to Apply Chemicals and Cleaning Solvents, High Pressure, Low Pressure

Page 9

HOW TO USE SPRAY WAND

Your pressure washer is equipped with a multi-adjustable spray wand with both high and low pressure settings. The high pressure setting is for cleaning and rinsing, the low pressure setting is for applying chemicals or cleaning solutions to surfaces.

When using the high pressure setting, DO NOT allow the jet-like spray to come

in contact with unprotected skin, eyes, or with any pets or animals. Serious injury can occur.

Risk of injection or injury to person. DO

NOT direct discharge stream toward persons.

For high pressure operation, pull back

The high pressure spray from your

pressure washer is capable of causing damage to surfaces such as wood, glass, automobile paint, auto striping and trim, and delicate objects such as flowers and shrubs. Before spraying, check the item to be cleaned to assure yourself that it is strong enough to resist damage from the force of the spray.

HOW TO APPLY CHEMICALS AND CLEANING SOLVENTS

Applying chemicals or cleaning solvents is a low pressure operation. NOTE: Use only soaps and chemicals designed for pressure washer use. Do not use bleach.

the nozzle of the multi-adjustable spray wand as shown.

High

Pressure

To Apply chemicals:

1.Press chemical hose onto barbed fitting located near high pressure hose connection of pump as shown.

Barbed Fitting

The nozzle at the end of the multi- adjustable spray wand can be rotated to change the high pressure spray pattern from a 0º pencil stream to a 40º fan spray, as shown. Markings have been placed on the nozzle to help you select the spray pattern.

40º fan spray

 

0º pencil stream

 

 

 

For low pressure operation, extend the nozzle of the multi-adjustable spray wand as shown.

Low

Pressure

2.Place other end of chemical hose with filter on it into container holding chemical/cleaning solution. NOTE: For every 7 gallons of water pumped 1 gallon of chemical/cleaning solution will be used.

3.Set multi-adjustable nozzle to low pressure setting. See How To Use Spray Wand instruction in this section.

4.After use of chemicals, place chemical hose into container of clean water and draw clean water through chemical injection system to rinse system thoroughly. If chemicals remain in the pump it could be damaged. Pumps damaged due to chemicals will not be covered under warranty.

NOTE: Chemicals and soaps will not siphon when spray wand is in the high pressure setting.

9- ENG

A04032

Image 9
Contents Structioin N M Anual Consumer Safety Information Important Safety InstructionsRisk of Explosion or Fire Risk of Explosion or Fire Risk to BreathingRisk to Fluid Injection Risk of Chemical Burn Risk of Electrical ShockRisk of HOT Surfaces Risk of Injury from Spray Risk of Unsafe OperationCarton Contents Basic Elements of a Pressure Washer Operating InstructionsBasic Elements of AN Engine Pressure Washer TerminologyPressure Washer Operating Features High Pressure HOW to Apply Chemicals and Cleaning Solvents40º fan spray 0º pencil stream Low PressureShutting Down StartingNozzle Cleaning MaintenanceHOW to Clean the Water Inlet Filter Engine PumpStorage EnginePressure Washer Trouble Shooting Guide Normal use Water leaking at After periodGun/spray wand Connection Water leakingENG A04032 Warranty

DTT2450 specifications

The Delta DTT2450 is a cutting-edge temperature and humidity data logger that caters to a wide array of industrial and scientific applications. Renowned for its precision and reliability, this device is integral in environments such as pharmaceutical, food storage, and environmental monitoring, where maintaining specific temperature and humidity levels is crucial.

One of the main features of the Delta DTT2450 is its dual-channel capability, allowing simultaneous measurement of both temperature and humidity. This enhances its versatility, enabling users to monitor two critical environmental parameters with a single device. The logger boasts a wide measurement range, with temperature readings typically spanning from -40°C to +80°C and humidity levels from 0% to 100% relative humidity. This broad range makes it suitable for a variety of settings.

The device operates using an advanced semiconductor and capacitive sensor technology, resulting in excellent accuracy and response time. The DTT2450 is designed with user-friendliness in mind, equipped with a large, easy-to-read LCD display that provides real-time data monitoring. Additionally, its intuitive interface allows for easy navigation through settings and data retrieval, even for users with minimal technical expertise.

A notable characteristic of the Delta DTT2450 is its data storage capability. It can store a significant amount of data points, allowing for extensive logging periods without the need for frequent data downloading. The logger supports various data sampling rates, customizable according to user requirements, ensuring optimal data collection in varying scenarios.

Connectivity is facilitated via USB, enabling quick and straightforward data transfer to computers for analysis. The device is compatible with specialized software that provides comprehensive data analysis and reporting tools, aiding in compliance with industry standards.

With a robust design, the DTT2450 can withstand challenging environmental conditions, making it a dependable choice for both indoor and outdoor use. It is also equipped with a long-lasting battery, ensuring extended operational periods and reducing maintenance interruptions.

In summary, the Delta DTT2450 stands out for its dual-channel monitoring, accuracy, and user-friendly design, making it an excellent investment for businesses and organizations keen on maintaining optimal environmental conditions effectively.