Turn cover to the left (counterclockwise) and remove it and filter from flange. Discard filter.
oClean cover and flange thoroughly.
oInsert new filter into cover.
oPosition cover and filter firmly against flange with tab on cover inserted into lower left comer of slot in
flange.
Push cover firmly against flange and turn it to the right (clockwise) as far as it will go. Be sure retain- ers are locked around flange.
Shut off the engine and turn off the water supply.
Separate the nozzle from the nozzle extension,
oRotate to stream setting.
,,Remove orifice from the end of the nozzle using the allen wrench included with the kit or a 2ram or 5/64 allen wrench.
CLEAN/REPLACE SPARK PLUG
| • Use the wire included in the kit or a small paper clip | |
Change the spark plug every 100 hours of operation or | to free the foreign materials clogging or restricting | |
once each year, whichever comes .first. This will help | the nozzle. | |
| ||
your engine to start easier and run better. Replace with |
| |
champion RN4C or equivalent type spai'kplug. |
| |
Clean area around spark plug |
| |
Remove and inspect spark plug. |
| |
Replace spark plug if electrodes are pitted, burned | insert wire into orifice and turn back and forth to | |
or porcelain is cracked. For replacement use | clear obstruction. | |
Champion RN4C only. | Remove additional debris by back flushing water | |
Check electrode gap with wire feeler gauge and set | ||
supply through wand. Back flush between 30 to 60 | ||
gap at 0.030 (0.76mm) if necessary. | ||
seconds. Turn wand to stream spray and move noz- | ||
SET PLUG GAP AT 0.030 inch | ||
zle from tow to high pressure while flushing. | ||
(0.76 ram) | ||
|
NOZZLE MAINTENANCE
If the nozzle becomes restrictedor clogged with foreign materials, such as dirt, excessive pump pressure may develop. A partially clogged nozzle can cause a pulsing sensation during use. This generally is not a pump
related problem, but rather a clogged or partially restricted nozzle.
If the nozzle becomes clogged or partially restricted, immediately clean the nozzle with the kit included with your pressure washer by following these instructions:
Reinstall orifice into nozzle. DO NOT overtighten.
o Reconnect nozzle to nozzle extension.
•Reconnect the water supply, turn ON the water, and start the engine.
-Test the pressure washer by operating with nozzle in the high and the tow pressure positions.