OPERATING PROCEDURES (cont'd)

Pressure adjustment:

Annovi Reverberi

The pressure setting is preset at the factory to achieve optimum pressure and cleaning. If you need to lower the pressure, it can be accomplished by two methods.

The first method is to back away from the surface to be cleaned. The further away you are, the less the pressure will be on the surface to be cleaned.

The second method is to adjust the pressure regulator on the pump. Please read the following instructions for adjusting the pressure regulator:

Refer to page 16 and 17 to identify the pump that is on your pressure washer. The pressure is not adjust- able on DAPC, Faip, Karcher, or smaller Giant pumps.

The Annovi Reverberi, Cat, General and larger Giant pumps pressure can be lowered by turning the pressure regulator counterclockwise. Refer to the illustrations to the right to identify your pressure regulator.

Once you have finished using your pressure washer, return the pressure regulator to its original position by turning it clockwise.

DO NOT attempt to increase pump pres- sure. A higher pressure setting than the factory set pressure will damage pump.

CAT

General

Giant (beltdriven) P316

Giant P303

(unloader mounted on frame)

Giant (beltdriven) P316

(unloader mounted on pump)

14 — ENG

Image 14
Contents Pressure Washer Service Policy Index Frequently Asked Questions Important Safety Instructions Safety Owners Responsibilities Manual for Safety, Operation, and Maintenance InstructionsCleaning Units GPM x PSI GlossaryBOX Contents AssemblyMulti-Reg Hi-Low/Quick Connect Dual Lance Illustration a Illustration BIllustration C Operating ProceduresStart-Up Operating Procedures contd Connect Water Turn on WaterOperating Procedures contd High Pressure Operation Multi-Reg High Pressure Setting Hi-Low Dual LanceQuick Connect with Nozzles Quick Connect Coupler Illustration a Operating Procedures contd Low Pressure OperationMulti-Reg Low Pressure Setting Operating Procedures contd Pressure adjustment Annovi ReverberiThermal Relief Valve Operating Procedures contd Chemical Flow AdjustmentShut Down Procedure Turn off WaterMaintenance HoursWas shipped from the factory Maintenance contdFollowing pump 2200 psi Following pump 2400 psi With 10W30 synthetic oilMaintenance contd Nozzle cleaning Dual Lance Soap NozzleMaintenance contd Water Inlet Screen Cleaning Storage & Winter Storage Preparation for StorageTroubleshooting Guide Problem Cause CorrectionEngine will not idle down AssemblyIdle down assembly if If equipped with Idle downLimited Warranty General Manual for