MAINTENANCE (cont'd)

Nozzle cleaning:

If the nozzle becomes clogged with foreign materials, such as dirt, excessive pressure may develop. If the nozzle becomes partially clogged or restricted, the pump pressure will pulsate. Clean the nozzle immediately using the nozzle kit supplied and the following instructions:

Multi-Reg Wand/Lance:

1.Shut off the pressure washer and turn off the water supply.

2.Disconnect spark plug wire.

3.Pull trigger on gun handle to relieve any water pressure.

4.Disconnect the wand/lance from the gun.

5.Remove the nozzle from the end of the wand with the 2mm allen wrench provided as shown in Figure 16.

6.Clean the nozzle using the nozzle cleaner provided or a straightened paper clip. Insert into the nozzle end and work back and forth until obstruction is removed. See Figure 17.

7.Direct water supply into nozzle end to backflush loosened particles for 30 seconds. See Figure 18.

8.Reassemble the nozzle to the wand. Tighten securely to prevent leaks.

9.Reconnect wand/lance to gun and turn on water supply.

10.Start pressure washer and place wand/lance into high pressure setting to test.

Figure 16

Figure 17

Figure 18

Dual Lance/Hi-Low Lance/Quick Connect Lance:

1.Shut off the pressure washer and turn off the water supply.

2.Disconnect spark plug wire.

3.Pull trigger on gun handle to relieve any water pressure.

4.Disconnect the wand/lance from the gun.

5.Remove the high-pressure nozzle from the lance. Remove any obstructions with the nozzle cleaning tool provided and backflush with clean water.

Note: For pressure washers with Dual-Lance wands as shown here, do not remove the soap nozzle. The soap nozzle can be identified as having the larger hole in the nozzle. See Figure19.

6.Direct water supply into nozzle end to backflush loosened particles for 30 seconds.

7.Reassemble the nozzle to the lance using teflon tape to prevent leaks. Note: Teflon tape is only needed on nozzles for dual-lance and hi/low wands. Tighten securely.

8.Reconnect wand/lance to gun and turn on water supply.

9.Start pressure washer and place wand/lance into high pressure setting to test.

Dual Lance

Figure 19

Soap

Nozzle

18 — ENG

Image 18
Contents Pressure Washer Service Policy Index Frequently Asked Questions Important Safety Instructions Safety Owners Responsibilities Manual for Safety, Operation, and Maintenance InstructionsCleaning Units GPM x PSI GlossaryBOX Contents AssemblyMulti-Reg Hi-Low/Quick Connect Dual Lance Illustration a Illustration BOperating Procedures Start-UpIllustration C Operating Procedures contd Connect Water Turn on WaterOperating Procedures contd High Pressure Operation Multi-Reg High Pressure Setting Hi-Low Dual LanceQuick Connect with Nozzles Quick Connect Coupler Operating Procedures contd Low Pressure Operation Multi-Reg Low Pressure SettingIllustration a Operating Procedures contd Pressure adjustment Annovi ReverberiThermal Relief Valve Operating Procedures contd Chemical Flow AdjustmentShut Down Procedure Turn off WaterMaintenance HoursWas shipped from the factory Maintenance contdFollowing pump 2200 psi Following pump 2400 psi With 10W30 synthetic oilMaintenance contd Nozzle cleaning Dual Lance Soap NozzleMaintenance contd Water Inlet Screen Cleaning Storage & Winter Storage Preparation for StorageTroubleshooting Guide Problem Cause CorrectionEngine will not idle down AssemblyIdle down assembly if If equipped with Idle downLimited Warranty General Manual for