Troubleshooting Tips
Save time and money! Review the chart on this page first and you may not need to call for service.
Problem | Possible Causes | What To Do | |
|
|
|
|
No Hot Water | Hot water tempering valve | Repair/replace as necessary | |
|
| fouled |
|
|
|
|
|
| Pressure imbalance (over 5 psi) | Locate and repair cause of imbalance. | |
| between hot and cold water lines |
| |
|
|
|
|
| Fouled pressure regulator valve | Repair/replace as necessary | |
|
|
|
|
| Cold water line blocked | Repair as necessary. | |
Low Hot Water | Fouled pressure limiting Valve | Repair/replace as necessary | |
Pressure | Strainer |
| |
Water too Hot | Tempering valve malfunction | Repair/replace as necessary. | |
|
|
|
|
| System oversized for customer | Cover a solar collector/contact installer. | |
| requirements |
| |
Gas coming from Hot | Result of system operating | Run tap to allow gas to escape. | |
Water tap | but water not being used |
| |
| Corroded Anode | Replace | |
|
|
|
|
!CAUTION: For your safety DO NOT attempt repair of electrical wiring, thermostats, heating elements or other safety devices. Refer repairs to qualified service personnel.
35