Pentair CH installation manual GAS Connections, GAS Line Installations

Page 12

Installation (contd.)

12

 

 

GAS CONNECTIONS

GAS LINE INSTALLATIONS

Before installing the gas line, be sure to check which gas the heater has been designed to burn. This is important because different types of gas require different gas pipe sizes. The rating plate on the heater will indicate which gas the heater is designed to burn. Tables 7-9, on pages 12 and 13, shows which size pipe is required for the distance from the gas meter to the heater. The table is for natural gas at a specific gravity of .65 and propane at specific gravity of 1.5.

When sizing gas lines, calculate three (3) additional feet of straight pipe for every elbow used.

When installing the gas line, avoid getting dirt, grease or other foreign material in the pipe as this may cause damage to the gas valve, which may result in heater failure.

The gas meter should be checked to make sure that it will supply enough gas to the heater and any other appliances that may be used on the same meter.

The gas line from the meter will usually be of a larger size than the gas valve supplied with the heater. Therefore a reduction of the connecting gas pipe will be necessary. Make this reduction as close to the heater as possible.

The heater and any other gas appliances must be disconnected from the gas supply piping system during any pressure testing on that system, (greater that ½ PSIG).

The heater and its gas connection must be leak tested before placing the heater in operation. Do not use flame to test the gas line. Use soapy water or another nonflammable method.

A manual main shut-off valve must be installed externally to the heater.

WARNING

Do not install the gas line union inside the heater cabinet. This will void your warranty.

Pipe Sized For Length Of Run In Equivalent Feet

 

 

 

 

 

 

 

Table 7.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIPE SIZING FOR GAS LINE CONNECTIONS

 

 

 

 

 

 

 

 

MAXIMUM EQUIVALENT PIPE LENGTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural gas at 1000 B.T.U. per Cubic Foot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Propane Gas at 2500 B.T.U. per Cubic Foot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2”

3/4”

1”

1-1/4”

1-1/2”

 

2”

2-1/2”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

NAT

PRO

NAT

 

PRO

NAT

PRO

NAT

PRO

NAT

 

PRO

 

NAT

PRO

NAT

PRO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75 & 100

20’

50’

50’

 

150’

150’

600’

-

-

-

 

-

 

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

10’

40’

50’

 

150’

150’

600’

-

-

-

 

-

 

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

-

20’

30’

 

80’

125’

250’

450’

600’

-

 

-

 

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250

-

10’

20’

 

50’

70’

150’

250’

500’

600’

 

-

 

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

-

-

10’

 

30’

50’

100’

200’

350’

400’

 

600’

 

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350

-

-

10’

 

20’

30’

70’

125’

250’

250’

 

500’

 

500’

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

-

-

-

 

10’

20’

60’

100’

150’

200’

 

450’

 

400’

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

525

-

-

-

 

5’

15’

35’

65’

150’

130’

 

360’

 

390’

700’

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

750

-

-

-

 

-

-

20’

35’

80’

75’

 

180’

 

260’

600’

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

900

-

-

-

 

-

-

15’

20’

50’

45’

 

80’

 

150’

360’

400’

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P/N 472128

Rev. C 1-22-04

Image 12
Contents For Your Safety Read Before Operating What to do if YOU Smell GASFor additional free copies of this manual call 800 Table of Contents Code Requirements Important NoticesWarranty Information Safety RulesProduct Identification Operation contdFor Your Safety Read Before Lighting Lighting InstructionsTo Turn OFF GAS to Heater Dual Temperature Control System Operating ControlsMaintenance Instructions Energy Saving TipsSpring and Fall Operation Winter OperationMaintenance contd Chemical BalanceIf pH becomes too high over alkaline, it has these effects Alkalinity High LowInstallation Instructions SpecificationsInstallation contd Plumbing ConnectionsPlumbing Water Connections Insulating the High LimitsGAS Line Installations GAS ConnectionsRegulated Manifold Pressure Test Outdoor Installation only VentilationFront Stack Type Indoor Draft Hood KIT MiniMax CH Millivolt Wiring Diagram ElectricalTroubleshooting General Heater Short Cycling Rapid On and Off OperationMinimax CH Heater ALL Models MiniMax CH Parts List MiniMax CH Parts List, contd Rev. C MiniMax CH 150 IID Model Operating Instructions To Turn OFF GAS to ApplianceOperation Safety Lockout Indicator Light Description Thermostat Knob StopperTroubleshooting Controls Heat HeatTroubleshooting Controls Installation Transformer Wiring InstructionRegulated Manifold Pressure Test Electronic Ignition Wiring DiagramRemote Switch Dual Therm IID only Wire RemoteMinimax CH Heater 150 IID Model MiniMax CH Parts List 150 IID Model MiniMax CH Parts List 150 IID Model, contd Rev. C Pentair Pool Products, Inc
Related manuals
Manual 36 pages 27.89 Kb

CH specifications

Pentair CH is a leading provider of advanced water treatment solutions, known for its innovative approaches in delivering high-quality water through cutting-edge technologies. Designed for both residential and commercial use, Pentair CH focuses on enhancing water quality and efficiency while promoting sustainability.

One of the standout features of Pentair CH products is their robust filtration systems. The company's advanced multi-stage filtration technology ensures that water is treated effectively, removing impurities and contaminants that can affect taste, odor, and safety. The filtration process often includes a combination of activated carbon, reverse osmosis, and UV sterilization, allowing for comprehensive protection against a wide range of pollutants.

Moreover, the Pentair CH technology is designed with user convenience in mind. Many models come equipped with smart features that allow users to monitor water quality and consumption through mobile apps. This connectivity not only helps in tracking usage patterns but also alerts users about maintenance needs, ensuring optimal performance and longevity of the system.

Energy efficiency is another hallmark of Pentair CH appliances. The company emphasizes the development of energy-saving designs that minimize electricity consumption while maximizing output. This commitment to environmental stewardship is reflected in its eco-friendly materials and manufacturing processes, making Pentair CH an excellent choice for those looking to reduce their ecological footprint.

Durability and reliability are key characteristics of Pentair CH products. The systems are engineered to withstand various water conditions and climatic changes, providing consistent performance over an extended lifespan. The use of high-grade materials and rigorous testing standards further underscores the brand’s commitment to quality.

Pentair CH also offers a range of customized solutions tailored to meet the specific needs of different customers. Whether addressing the requirements of a large commercial facility or a family home, the flexibility in product design ensures that users can find the perfect fit for their water treatment needs.

In conclusion, Pentair CH stands out in the water treatment industry with a comprehensive product lineup characterized by state-of-the-art filtration technologies, user-centric design, energy efficiency, durability, and flexibility. These features combine to provide users with safe, clean, and great-tasting water, reinforcing Pentair CH’s position as a trusted leader in water treatment solutions.