Pentair CH installation manual Operating Controls, Dual Temperature Control System

Page 6
Figure 6.

Operation (contd.)

6

 

 

OPERATING (CONTROLS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dual Temperature Control System

 

 

 

 

 

 

 

For convenience and economy all MiniMax CH

 

 

 

 

 

 

 

heaters are equipped with two thermostats on the

 

 

 

 

 

 

 

front of the heater control panel; see Figure 5.

POOL

 

 

 

 

 

SPA

THERMOSTAT KNOB STOPPER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Each thermostat is equipped with a mechanical

 

 

 

 

 

 

 

 

 

 

stop that can be locked or unlocked with use of a

 

 

 

 

 

 

 

screwdriver to prevent temperatures in excess of

 

 

 

 

 

 

 

that desired by the user; see Figure 6.

 

 

 

 

 

 

 

The maximum setting can be adjusted by

COLD POOL TEMP

HOT COLD SPA TEMP HOT

loosening the screw "A" and turning the stopper

dial to desired maximum setting. Lock the setting

 

 

 

 

 

 

Figure 5.

by tightening the screw. The Mechanical stop is

 

 

 

 

 

 

 

under the knob. Ensure that the knob is stopping at the correct position when the knob is rotated clockwise from a lower temperature position. (See Thermostat Adjustment.)

NOTE

To eliminate error due to piping heat losses, measure pool temperature with an accurate thermometer directly at the pool or spa.

THERMOSTAT ADJUSTMENT

The knob with locking feature eliminates the need for constant thermostat adjustments. Set the knob pointer to the desired pool or spa temperature.

If further adjustment is needed, rotate the knob until the

 

desired temperature is obtained. This knob position

 

corresponding to your desired maximum pool or spa

 

temperature may now be preset (locked) by the knob

 

stopper which prevents the knob from being turned

 

beyond the maximum temperature you set.

Knob Stopper

 

POWER (THERMOSTAT SELECT) SWITCH

Screw A

The Pool/Off/Spa switch allows the heater to be turned off when heating is not desired.

1.“Pool” position - Maintains selected pool temperature.

2.“Off” position - Heater will not come on regardless of drop in pool or spa temperature.

3.“Spa” position - This allows separate control of spa water temperature or an alternate lower pool temperature.

P/N 472128

Rev. C 1-22-04

Image 6
Contents For Your Safety Read Before Operating What to do if YOU Smell GASFor additional free copies of this manual call 800 Table of Contents Code Requirements Important NoticesProduct Identification Warranty InformationSafety Rules Operation contdFor Your Safety Read Before Lighting Lighting InstructionsTo Turn OFF GAS to Heater Dual Temperature Control System Operating ControlsSpring and Fall Operation Maintenance InstructionsEnergy Saving Tips Winter OperationIf pH becomes too high over alkaline, it has these effects Maintenance contdChemical Balance Alkalinity High LowInstallation Instructions SpecificationsInstallation contd Plumbing ConnectionsPlumbing Water Connections Insulating the High LimitsGAS Line Installations GAS ConnectionsRegulated Manifold Pressure Test Outdoor Installation only VentilationFront Stack Type Indoor Draft Hood KIT MiniMax CH Millivolt Wiring Diagram ElectricalTroubleshooting General Heater Short Cycling Rapid On and Off OperationMinimax CH Heater ALL Models MiniMax CH Parts List MiniMax CH Parts List, contd Rev. C MiniMax CH 150 IID Model Operating Instructions To Turn OFF GAS to ApplianceOperation Safety Lockout Indicator Light Description Thermostat Knob StopperTroubleshooting Controls Heat HeatTroubleshooting Controls Installation Transformer Wiring InstructionRegulated Manifold Pressure Test Electronic Ignition Wiring DiagramRemote Switch Dual Therm IID only Wire RemoteMinimax CH Heater 150 IID Model MiniMax CH Parts List 150 IID Model MiniMax CH Parts List 150 IID Model, contd Rev. C Pentair Pool Products, Inc
Related manuals
Manual 36 pages 27.89 Kb

CH specifications

Pentair CH is a leading provider of advanced water treatment solutions, known for its innovative approaches in delivering high-quality water through cutting-edge technologies. Designed for both residential and commercial use, Pentair CH focuses on enhancing water quality and efficiency while promoting sustainability.

One of the standout features of Pentair CH products is their robust filtration systems. The company's advanced multi-stage filtration technology ensures that water is treated effectively, removing impurities and contaminants that can affect taste, odor, and safety. The filtration process often includes a combination of activated carbon, reverse osmosis, and UV sterilization, allowing for comprehensive protection against a wide range of pollutants.

Moreover, the Pentair CH technology is designed with user convenience in mind. Many models come equipped with smart features that allow users to monitor water quality and consumption through mobile apps. This connectivity not only helps in tracking usage patterns but also alerts users about maintenance needs, ensuring optimal performance and longevity of the system.

Energy efficiency is another hallmark of Pentair CH appliances. The company emphasizes the development of energy-saving designs that minimize electricity consumption while maximizing output. This commitment to environmental stewardship is reflected in its eco-friendly materials and manufacturing processes, making Pentair CH an excellent choice for those looking to reduce their ecological footprint.

Durability and reliability are key characteristics of Pentair CH products. The systems are engineered to withstand various water conditions and climatic changes, providing consistent performance over an extended lifespan. The use of high-grade materials and rigorous testing standards further underscores the brand’s commitment to quality.

Pentair CH also offers a range of customized solutions tailored to meet the specific needs of different customers. Whether addressing the requirements of a large commercial facility or a family home, the flexibility in product design ensures that users can find the perfect fit for their water treatment needs.

In conclusion, Pentair CH stands out in the water treatment industry with a comprehensive product lineup characterized by state-of-the-art filtration technologies, user-centric design, energy efficiency, durability, and flexibility. These features combine to provide users with safe, clean, and great-tasting water, reinforcing Pentair CH’s position as a trusted leader in water treatment solutions.