Pentair CH For Your Safety Read Before Lighting, Lighting Instructions, To Turn OFF GAS to Heater

Page 5
Figure 3.

Operation (contd.)

5

MINIMAX CH MILLIVOLT LIGHTING/OPERATION-NATURAL GAS & PROPANE

FOR YOUR SAFETY: READ BEFORE LIGHTING

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life and property damage.

Since propane gas is heavier than air, escaping propane will accumulate and remain at ground level. Do not attempt to light the heater. If you suspect a propane leak, lighting the heater can result in a fire or explosion which can cause personal injury, death, and property damage.

A.This heater is equipped with a pilot which must be lighted manually. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any heater.

-Do not touch any electrical switch; do not use any phone in your building.

-Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

-If you cannot reach your gas supplier, call the Fire Department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it. Call a qualified service technician. Forced or attempted repair may result in a fire or explosion.

D.Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to the lowest setting.

3.Turn off electric power to the heater.

4.Push in gas control knob slightly and turn clock-

wise to “OFF”.

Robertshaw Millivolt Gas Valve

Honeywell Millivolt Gas Valve

Figure 1.

Figure 2.

Gas control knobs shown in “OFF” position.

NOTE

Knob cannot be turned from “Pilot to “OFF”” unless knob is pushed in slightly. DO NOT FORCE.

5.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety informa- tion above. If you don't smell gas, go to the next step.

6.Push in gas control knob slightly and turn counter-

clockwise to “Pilot”.

7.Push the control knob all the way and hold in. Immediately light the pilot with Presslite matchless ignition system by pressing the red igniter button (located at the panel next to the gas valve). Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4 through 7.

If knob does not pop up when released, stop and immediately call your service technician or gas

supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

8.Turn knob on gas control

counterclockwise to “ON”.

9.Replace the control access door.

10.Set the thermostat to the

desired setting.

Figure 4. Pilot

TO TURN OFF GAS TO HEATER

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the heater if service is to be performed.

3.Remove control access door.

4.Push in gas control knob slightly and turn clockwise to "OFF". Do not force.

5.Replace control access door.

Rev. C 1-22-04

P/N 472128

Image 5
Contents For additional free copies of this manual call 800 For Your Safety Read Before OperatingWhat to do if YOU Smell GAS Table of Contents Important Notices Code RequirementsSafety Rules Warranty InformationProduct Identification Operation contdTo Turn OFF GAS to Heater For Your Safety Read Before LightingLighting Instructions Operating Controls Dual Temperature Control SystemEnergy Saving Tips Maintenance InstructionsSpring and Fall Operation Winter OperationChemical Balance Maintenance contdIf pH becomes too high over alkaline, it has these effects Alkalinity High LowSpecifications Installation InstructionsPlumbing Installation contdPlumbing Connections Insulating the High Limits Water ConnectionsGAS Connections GAS Line InstallationsRegulated Manifold Pressure Test Ventilation Outdoor Installation onlyFront Stack Type Indoor Draft Hood KIT Electrical MiniMax CH Millivolt Wiring DiagramHeater Short Cycling Rapid On and Off Operation Troubleshooting GeneralMinimax CH Heater ALL Models MiniMax CH Parts List MiniMax CH Parts List, contd Rev. C MiniMax CH 150 IID Model Operation Operating InstructionsTo Turn OFF GAS to Appliance Safety Lockout Thermostat Knob Stopper Indicator Light DescriptionHeat Heat Troubleshooting ControlsTroubleshooting Controls Regulated Manifold Pressure Test InstallationTransformer Wiring Instruction Diagram Electronic Ignition WiringWire Remote Remote Switch Dual Therm IID onlyMinimax CH Heater 150 IID Model MiniMax CH Parts List 150 IID Model MiniMax CH Parts List 150 IID Model, contd Rev. C Pentair Pool Products, Inc
Related manuals
Manual 36 pages 27.89 Kb

CH specifications

Pentair CH is a leading provider of advanced water treatment solutions, known for its innovative approaches in delivering high-quality water through cutting-edge technologies. Designed for both residential and commercial use, Pentair CH focuses on enhancing water quality and efficiency while promoting sustainability.

One of the standout features of Pentair CH products is their robust filtration systems. The company's advanced multi-stage filtration technology ensures that water is treated effectively, removing impurities and contaminants that can affect taste, odor, and safety. The filtration process often includes a combination of activated carbon, reverse osmosis, and UV sterilization, allowing for comprehensive protection against a wide range of pollutants.

Moreover, the Pentair CH technology is designed with user convenience in mind. Many models come equipped with smart features that allow users to monitor water quality and consumption through mobile apps. This connectivity not only helps in tracking usage patterns but also alerts users about maintenance needs, ensuring optimal performance and longevity of the system.

Energy efficiency is another hallmark of Pentair CH appliances. The company emphasizes the development of energy-saving designs that minimize electricity consumption while maximizing output. This commitment to environmental stewardship is reflected in its eco-friendly materials and manufacturing processes, making Pentair CH an excellent choice for those looking to reduce their ecological footprint.

Durability and reliability are key characteristics of Pentair CH products. The systems are engineered to withstand various water conditions and climatic changes, providing consistent performance over an extended lifespan. The use of high-grade materials and rigorous testing standards further underscores the brand’s commitment to quality.

Pentair CH also offers a range of customized solutions tailored to meet the specific needs of different customers. Whether addressing the requirements of a large commercial facility or a family home, the flexibility in product design ensures that users can find the perfect fit for their water treatment needs.

In conclusion, Pentair CH stands out in the water treatment industry with a comprehensive product lineup characterized by state-of-the-art filtration technologies, user-centric design, energy efficiency, durability, and flexibility. These features combine to provide users with safe, clean, and great-tasting water, reinforcing Pentair CH’s position as a trusted leader in water treatment solutions.