Pentair CH installation manual Safety Lockout

Page 25

Operation (contd.)

25

 

 

MINIMAX CH (150 IID) ELECTRONIC IGNITION LIGHTING/OPERATION - PROPANE

FOR YOUR SAFETY: READ BEFORE LIGHTING

NOTE

The MiniMax CH propane models have special features for additional safety and protection. Read the safety instructions for natural gas (page A-2) before proceeding.

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life and property damage.

Since propane gas is heavier than air, escaping propane will accumulate and remain at ground level. Do not attempt to light the heater. If you suspect a propane leak, lighting the heater can result in a fire or explosion which can cause personal injury, death, and property damage.

WHAT TO DO IF YOU SMELL GAS

-Do not try to light matches or lighter.

-Do not try to light any heater.

-Do not touch any electrical switch; do not use any phone in your building.

-Shut off gas line at propane tank.

Safety Lockout:

-Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

-If you cannot reach your gas supplier, call the Fire Department.

-Do not tamper with the heater because it is dangerous and voids all warranties.

This MiniMax CH Propane Heater is equipped with a 100% safety lockout feature. If the pilot does not light within a maximum of 90 seconds, lockout will occur.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to the lowest setting.

3.Turn off electric power to the heater.

4.This heater is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

5.Remove the control access door.

6.Push in gas control knob slightly and turn clock-

wise to “OFF”.

7.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information on page 5. If you don't smell gas, go to the next step.

8.Turn knob on gas control counterclockwise to “ON”; see Figure 2.

9. Replace the control access door.

10.Turn on the electrical power to the heater.

11.Set the thermostat to the desired setting.

12.If the heater will not operate, follow the instruc- tions "To Turn Off Gas To Heater" and call your service technician or gas supplier.

Gas

Inlet

ON

OFF

Figure 2. Gas control knob shown in “ON” position.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the heater if service is to be performed.

3.Remove control access door.

4.Push in gas control knob slightly and turn

clockwise to "OFF". Do not force.

5.Replace control access door.

Rev. C 1-22-04

A-3

P/N 472128

Image 25
Contents What to do if YOU Smell GAS For Your Safety Read Before OperatingFor additional free copies of this manual call 800 Table of Contents Important Notices Code RequirementsSafety Rules Warranty InformationProduct Identification Operation contdLighting Instructions For Your Safety Read Before LightingTo Turn OFF GAS to Heater Operating Controls Dual Temperature Control SystemEnergy Saving Tips Maintenance InstructionsSpring and Fall Operation Winter OperationChemical Balance Maintenance contdIf pH becomes too high over alkaline, it has these effects Alkalinity High LowSpecifications Installation InstructionsPlumbing Connections Installation contdPlumbing Insulating the High Limits Water ConnectionsGAS Connections GAS Line InstallationsRegulated Manifold Pressure Test Ventilation Outdoor Installation onlyFront Stack Type Indoor Draft Hood KIT Electrical MiniMax CH Millivolt Wiring DiagramHeater Short Cycling Rapid On and Off Operation Troubleshooting GeneralMinimax CH Heater ALL Models MiniMax CH Parts List MiniMax CH Parts List, contd Rev. C MiniMax CH 150 IID Model To Turn OFF GAS to Appliance Operating InstructionsOperation Safety Lockout Thermostat Knob Stopper Indicator Light DescriptionHeat Heat Troubleshooting ControlsTroubleshooting Controls Transformer Wiring Instruction InstallationRegulated Manifold Pressure Test Diagram Electronic Ignition WiringWire Remote Remote Switch Dual Therm IID onlyMinimax CH Heater 150 IID Model MiniMax CH Parts List 150 IID Model MiniMax CH Parts List 150 IID Model, contd Rev. C Pentair Pool Products, Inc
Related manuals
Manual 36 pages 27.89 Kb

CH specifications

Pentair CH is a leading provider of advanced water treatment solutions, known for its innovative approaches in delivering high-quality water through cutting-edge technologies. Designed for both residential and commercial use, Pentair CH focuses on enhancing water quality and efficiency while promoting sustainability.

One of the standout features of Pentair CH products is their robust filtration systems. The company's advanced multi-stage filtration technology ensures that water is treated effectively, removing impurities and contaminants that can affect taste, odor, and safety. The filtration process often includes a combination of activated carbon, reverse osmosis, and UV sterilization, allowing for comprehensive protection against a wide range of pollutants.

Moreover, the Pentair CH technology is designed with user convenience in mind. Many models come equipped with smart features that allow users to monitor water quality and consumption through mobile apps. This connectivity not only helps in tracking usage patterns but also alerts users about maintenance needs, ensuring optimal performance and longevity of the system.

Energy efficiency is another hallmark of Pentair CH appliances. The company emphasizes the development of energy-saving designs that minimize electricity consumption while maximizing output. This commitment to environmental stewardship is reflected in its eco-friendly materials and manufacturing processes, making Pentair CH an excellent choice for those looking to reduce their ecological footprint.

Durability and reliability are key characteristics of Pentair CH products. The systems are engineered to withstand various water conditions and climatic changes, providing consistent performance over an extended lifespan. The use of high-grade materials and rigorous testing standards further underscores the brand’s commitment to quality.

Pentair CH also offers a range of customized solutions tailored to meet the specific needs of different customers. Whether addressing the requirements of a large commercial facility or a family home, the flexibility in product design ensures that users can find the perfect fit for their water treatment needs.

In conclusion, Pentair CH stands out in the water treatment industry with a comprehensive product lineup characterized by state-of-the-art filtration technologies, user-centric design, energy efficiency, durability, and flexibility. These features combine to provide users with safe, clean, and great-tasting water, reinforcing Pentair CH’s position as a trusted leader in water treatment solutions.