Raypak 155C installation instructions Z223.1, Vent Piping

Page 13

VENT TERMINAL (Outdoor) OUTDOOR STACK

STEP 1 Line up (8) holes in jacket top with (8) holes in adapter assembly.

STEP 2 Lower entire outdoor stack assembly on to jacket top.

STEP 3 Secure with fasteners provided.

Fig. #9307

VENT TERMINAL (Indoor)

Locate and assemble as shown. Secure with screws supplied in envelope inside carton.

DRAFT HOOD

MOUNTING

SCREWS (8)

Fig. # 9308

horizontal runs of vent pipe and too many elbows. If installation requires horizontal non-vertical runs, the vent pipe must have a minimum of 1/4 inch per foot rise and should be supported at not less than five foot intervals. Plumbers tape, criss-crossed, will serve to space both horizontal and vertical piping. Gas vents supported only by the flashing and extending above the roof more than five feet should be securely guyed or braced to withstand snow and wind loads. We recommend use of insulated vent pipe spacer through the roofs and walls.

For protection against rain or blockage by snow, the vent pipe must terminate with a vent cap which com- plies with the local codes or, in the absence of such codes, latest edition of the National Fuel Gas Code,ANSI

Z223.1.

The discharge opening must be a minimum of two feet vertically from the roof surface and at least two feet higher than any part of the building within ten feet. Vent stack shall be at least five feet in vertical height above the drafthood outlet. The vent cap location shall have a minimum clearance of 4 feet horizontally from, and in no case above or below, unless a four foot horizontal distance is maintained, from electric meters, gas me- ters regulators and relief equipment.

The weight of the vent stack or chimney must not rest on boiler draft hood. Support must be provided in compliance with applicable codes. The boiler top and draft hood must be readily removeable for maintenance and inspection. Vent pipe should be adequately sup- ported to maintain proper clearances from combustible construction.

Type "B" double wall or equivalent vent pipe is recommended. However single wall metal vent pipe may be used as specified in the latest edition of the National Flue Gas Code ANSI Z 223.1.

10' OR LESS

VENT CAP

2' MIN

2' MIN

VENT PIPING

WARNING: Indoor boilers require a drafthood that must be connected to a vent pipe and properly vented to the outside. Failure to follow this procedure can cause fire or fatal carbon monoxide poisoning.

Vent piping the same size or larger than the draft hoodoutletisrecommended,however,whenthetotalvent height is at least ten (10) feet (draft hood relief opening to vent terminal), the vent pipe size may be reduced as specified in Chapter 10 of the latest edition National Fuel Gas Code, ANSI Z 223.1. As much as possible avoid long

5' MIN

VENT PIPE

DRAFT HOOD

HEATER

13

Fig. # 8119.0

Image 13
Contents What to do if YOU Smell GAS VersaPart TWO INSTALLATION/SERVICE Instructions ContentsBefore START-UP START-UP ProceduresBurners WaterMillivolt System Operating Instructions Electronic Ignition SystemsIID After START-UP Water Pressure SwitchVisual Inspection Basic Tips if Heater will not Fire Maintenance and Care ProceduresPool & SPA Water Chemistry Automatic Chlorinators and Chemical FeedersCold Weather Operation Pressure Switch Compression Fitting Return HeaderWinterizing the Pool & SPA Heater Installation Instructions General SpecificationsReceiving Equipment Clearances High Wind Conditions Outdoor Units only Combustion AIR Indoor Units only Indoor HeatersVenting Connections Vent Piping Z223.1Pipe Sizing for GAS Connections GAS Supply ConnectionsCompanion Flange Connections Plumbing for Water Connections LocationPressure Relief Valve Installation Auxiliary Bypass Valve AdjustmentUnitherm Governor Operation Internal Automatic BY-PASS ValveMillivolt System Electrical WiringElectronic Intermittent Ignition Device System IID Honeywell Intermittent Ignition DeviceANSI/NFPA Wiring Diagram KEYFig. #2182e Wiring Diagram Millivolt UnitsWiring Diagram 152148 Model 155 IID Temperature Controls Controls / Adjustments / ReplacementsGeneral Location of Controls View of Heater from Front View of Heater from BackFlame ROLL-OUT Safety Switch Pressure SwitchHigh Limits Burner Drawer Removal Pilot Removal and CleaningGAS Valve Removal Main Burner and Orifice RemovalUnitherm Governor U.G. Replacement Control Immersion Well ReplacementHeat Exchanger Removal Desooting Procedure Tube Replacement ProcedureCombustion Chamber Removal Refractory Panels TOP ViewTrouble Shooting Guide Electrical Millivolt Electrical Electronic Ignition IID Troubleshooting Honeywell S8600High Voltage Voltage Between 21.5-28.5 Voltage Outside Range 21.5-28.5 Electrical Solid State Thermostat IIDRAYPAK, INC Replacement Parts ListPage Page Page Warranty Exclusion

155C specifications

The Raypak 155C is a versatile and efficient heater designed for both residential and commercial applications. Renowned for its robust construction and reliable performance, this unit is an excellent choice for pool and spa heating as well as for providing comfortable ambient temperatures in enclosed or outdoor spaces.

One of the standout features of the Raypak 155C is its innovative copper heat exchanger, which is designed for maximum heat transfer efficiency. This technology allows for rapid heating capabilities, ensuring that water reaches the desired temperature quickly and effectively. The heat exchanger is also resistant to corrosion, thanks to its durable design, prolonging the unit's life and maintaining performance over time.

Designed with user convenience in mind, the Raypak 155C features an intuitive digital control system. This user-friendly interface allows for easy temperature adjustments and monitoring, giving users precise control over their heating requirements. An integrated diagnostic system is also included, providing real-time feedback on the heater's performance and alerting users to any potential issues, which helps in proactive maintenance.

Incorporating advanced safety features, the Raypak 155C includes a high limit switch and a water flow switch, ensuring safe operation at all times. These safety mechanisms prevent overheating and dry firing, protecting both the heater and the connected plumbing system.

The Raypak 155C is engineered for energy efficiency, meeting and exceeding industry standards. With a compact design, it ensures easy installation and integration into existing setups, making it a favorable choice for various applications. Its quiet operation adds to user comfort, allowing it to be installed in residential settings without causing disturbances.

With a heating capacity of 155,000 BTU, the Raypak 155C is capable of effectively heating larger pools and spas, making it ideal for homes with extensive water features. The heater is designed to run on natural gas or propane, providing flexibility based on user preferences and availability.

Overall, the Raypak 155C combines state-of-the-art technology with practical features, making it one of the top choices for those looking to enhance their pool experience or improve comfort levels in their outdoor areas. Its reliability, efficiency, and user-friendly features make it a valuable investment for any property.