Raypak 155C Electrical Wiring, Millivolt System, Honeywell Intermittent Ignition Device

Page 17

NOTE: To avoid water damage or scalding due to valve operation, drain pipe must be connected to valve outlet and run to a safe place of discharge. Drain pipe must be the same size as the valve discharge connection throughout its entire length and must pitch downward from the valve. No shut-off valve shall be installed between the relief valve and the drain line. Valve lever should be tripped at least once a year to ensure that waterways are clear.

ELECTRICAL WIRING

NOTE: If it is necessary to replace any of the original wiring, it must be replaced with 105°C wire or its equivalent, except all black wire must be replaced with 150°C wire or its equivalent.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

DANGER - SHOCK HAZARD - Make sure electrical power to the heater is disconnected to avoid potential serious injury or damage to components.

MILLIVOLT SYSTEM

The Millivolt System Residential Heater is equip- ped with a self-generating electrical system in which the electric current is provided by means of a pilot generator. No external electrical connections are re- quired.

ELECTRONIC INTERMITTENT IGNITION DEVICE SYSTEM (IID)

NOTE: When the electrical hookup to the heater requires both 24V and 115V or 240V, each input voltage must be isolated in separate conduit.

The Electronic Intermittent Ignition Device automati- cally lights the pilot and main burners upon a call for heat. The heater is supplied with a dual voltage trans- former for 120V or 240V input power hookup. Heaters are factory wired for 240V power supply.

NOTE: IID PROPANE UNITS ONLY: Heater is equipped with an electronic ignition device with a 100% safety lockout feature. If the heater fails to start or lockout, reset the ignition device by interrupting the power to the heater for 60 seconds.

CAUTION: If service replacement of the electronic ignition device is required, replace only with a 100% safety lockout device with 90 second trial for pilot ignition.

HONEYWELL

INTERMITTENT

IGNITION

DEVICE

Fig. # 8929.1

17

Image 17
Contents What to do if YOU Smell GAS VersaPart TWO INSTALLATION/SERVICE Instructions ContentsBefore START-UP START-UP ProceduresBurners WaterMillivolt System IID Electronic Ignition SystemsOperating Instructions Visual Inspection Water Pressure SwitchAfter START-UP Basic Tips if Heater will not Fire Maintenance and Care ProceduresPool & SPA Water Chemistry Automatic Chlorinators and Chemical FeedersWinterizing the Pool & SPA Heater Pressure Switch Compression Fitting Return HeaderCold Weather Operation Receiving Equipment General SpecificationsInstallation Instructions Clearances High Wind Conditions Outdoor Units only Venting Connections Indoor HeatersCombustion AIR Indoor Units only Vent Piping Z223.1Pipe Sizing for GAS Connections GAS Supply ConnectionsCompanion Flange Connections Plumbing for Water Connections LocationPressure Relief Valve Installation Auxiliary Bypass Valve AdjustmentUnitherm Governor Operation Internal Automatic BY-PASS ValveMillivolt System Electrical WiringElectronic Intermittent Ignition Device System IID Honeywell Intermittent Ignition DeviceANSI/NFPA Wiring Diagram KEYFig. #2182e Wiring Diagram Millivolt UnitsWiring Diagram 152148 Model 155 IID Temperature Controls Controls / Adjustments / ReplacementsGeneral Location of Controls View of Heater from Front View of Heater from BackHigh Limits Pressure SwitchFlame ROLL-OUT Safety Switch Burner Drawer Removal Pilot Removal and CleaningGAS Valve Removal Main Burner and Orifice RemovalHeat Exchanger Removal Control Immersion Well ReplacementUnitherm Governor U.G. Replacement Desooting Procedure Tube Replacement ProcedureCombustion Chamber Removal Refractory Panels TOP ViewTrouble Shooting Guide Electrical Millivolt High Voltage Troubleshooting Honeywell S8600Electrical Electronic Ignition IID Voltage Between 21.5-28.5 Voltage Outside Range 21.5-28.5 Electrical Solid State Thermostat IIDRAYPAK, INC Replacement Parts ListPage Page Page Warranty Exclusion

155C specifications

The Raypak 155C is a versatile and efficient heater designed for both residential and commercial applications. Renowned for its robust construction and reliable performance, this unit is an excellent choice for pool and spa heating as well as for providing comfortable ambient temperatures in enclosed or outdoor spaces.

One of the standout features of the Raypak 155C is its innovative copper heat exchanger, which is designed for maximum heat transfer efficiency. This technology allows for rapid heating capabilities, ensuring that water reaches the desired temperature quickly and effectively. The heat exchanger is also resistant to corrosion, thanks to its durable design, prolonging the unit's life and maintaining performance over time.

Designed with user convenience in mind, the Raypak 155C features an intuitive digital control system. This user-friendly interface allows for easy temperature adjustments and monitoring, giving users precise control over their heating requirements. An integrated diagnostic system is also included, providing real-time feedback on the heater's performance and alerting users to any potential issues, which helps in proactive maintenance.

Incorporating advanced safety features, the Raypak 155C includes a high limit switch and a water flow switch, ensuring safe operation at all times. These safety mechanisms prevent overheating and dry firing, protecting both the heater and the connected plumbing system.

The Raypak 155C is engineered for energy efficiency, meeting and exceeding industry standards. With a compact design, it ensures easy installation and integration into existing setups, making it a favorable choice for various applications. Its quiet operation adds to user comfort, allowing it to be installed in residential settings without causing disturbances.

With a heating capacity of 155,000 BTU, the Raypak 155C is capable of effectively heating larger pools and spas, making it ideal for homes with extensive water features. The heater is designed to run on natural gas or propane, providing flexibility based on user preferences and availability.

Overall, the Raypak 155C combines state-of-the-art technology with practical features, making it one of the top choices for those looking to enhance their pool experience or improve comfort levels in their outdoor areas. Its reliability, efficiency, and user-friendly features make it a valuable investment for any property.