Viking VEDV900 dimensions Install the Blower

Page 3

INSTALL THE BLOWER

ROOF INSTALLATIONS

1.Remove roofing nails from the upper 2/3 of the shingles around the cutout area and carefully lift the shingles to allow the back flashing sheet on the blower housing to fit under them.

2.Center the blower ring in the 11" diameter hole, making sure that the 1-1/4" diameter electrical wir- ing hole aligns with the hole in the wiring box.

3.Attach the blower to the roof with the six screws provided. All six holes in the back panel must be filled, or any moisture that may get inside the blower housing could leak into the house.

4.Using a good grade of roofing cement, seal all of the shingles around the housing and flashing sheet as well as the mounting screw heads.

5.Bring electrical wiring through the hole in the wiring box and secure it according to local codes.

Figure 4

 

 

BLACK

 

 

TO

 

 

BLACK

 

 

LINE IN

WHITE

 

120 VAC

GREEN

FROM

TO

LINE IN

TO

DOWNDRAFT

WHITE

VENTILATOR

 

GREEN

 

 

6.Make the electrical connections with the proper connector for the type of wiring being used. Con- nect white to white, black to black, and the green or bare wire to green. See Figure 4.

7.Replace wiring box cover and screws. Do not pinch wiring under the cover.

8.Check for free movement of the damper before installing housing cover and screws.

INSTALL THE BLOWER

WALL INSTALLATIONS

1.Place a large bead of caulk on the back side of the housing along the outer edge.

2.Center the blower ring in the 11" diameter hole, making sure that the 1-1/4" diameter electrical wiring hole aligns with the hole in the wiring box.

3.Attach blower to the wall with the six screws provided. All six holes in the back panel must be filled, or any moisture that may get inside the blower housing could leak into the house.

4.Using a good grade of caulk, seal all around the mounting screw heads.

5.Bring electrical wiring through the hole in the wiring box and secure it according to local codes.

6.Make the electrical connections with the proper connector for the type of wire being used. Connect white to white, black to black, and green or bare wire to green. See Figure 4.

7.Replace wiring box cover and screws. Do not pinch wiring under cover.

8.Check for free movement of the damper before installing housing cover and screws.

9.Top and side flanges of the back plate may be covered with trim strips. Do not block grille opening at bottom with trim. It will adversely affect perfor- mance of the blower.

3

Image 3
Contents Viking Model VEDV900 Exterior Mounted Blower SpecificationsPlan Installation ALL InstallationsPrepare the Blower Prepare the Installation LocationRoof Installations Wall InstallationsInstall the Blower USE and Care CleaningConnect 10 Round Ductwork Viking Range CorporationPlanification DE LA Pose Viking Modèle VEDV900 Ventilateur Monté À L’EXTÉRIEURAvertissementavertissement SpécificationsIllustration Préparation DE L’EMPLACEMENT DE PosePréparation DU Ventilateur Poses SUR LES Toits Poses SUR LES MursNoir Pose DU VentilateurPoses SUR LES Toits IlllustrationLubrification DU Moteur Raccordement DU Conduit Rond DE 25,4 CM 10 POUtilisation ET Entretien Nettoyage