Operator’s Manual | Second Edition • Fourth Printing |
|
|
|
|
FUNCTION TESTS
Function Tests
1Select a level test area free of obstructions.
2Pump the foot pedal to raise the base.
Result: The wheels should contact the ground.
3Pull the base lowering handle to fully lower the base.
Result: All four foot pads should come in firm contact with the ground.
4Connect the appropriate power source.
5Use the bubble level and adjust the leveling jacks until the machine is level and all four foot pads are in firm contact with the ground.
6Insert the key and turn to the ON position OR turn to platform controls.
7Pull out the red Emergency Stop button at the ground controls to the ON position.
8Twist to release the red Emergency Stop button
at the platform controls.
Result: The power light should come on. Within 1 to 4 seconds, all four display lights should turn on and remain on.
Test Interlock System
9 Pump the foot pedal to raise the base.
Result: The two foot pad display lights should be off.
10 Pull the base lowering handle to lower the base.
Result: The two foot pad display lights should be on.
11Pump the foot pedal to raise the base.
12Turn both the leveling jacks clockwise to the full down position.
13Pull the base lowering handle to lower the base.
Result: The base will lower and the two level sensor display lights should be off and remain off because the base is not level.
14 At the platform controls, push in the control activate button and rotate the up/down switch to the UP position, then the DOWN position.
Result: The platform up/down function should not operate.
Test Emergency Stop
15Use the bubble level and adjust the leveling jacks until the machine base is level. Be sure all four display lights are on.
16Push in the red Emergency Stop button at the ground controls.
17At the platform controls, push in the control activate button and rotate the up/down switch in each direction.
Result: The platform up/down function should not operate.
18Push in the red Emergency Stop button at the platform controls and pull out the red Emergency Stop button at the ground controls.
19At the platform controls, push in the control activate button and rotate the up/down switch in each direction.
Result: The platform up/down function should not operate.
14 | Genie IWP Super Series | Part No.48643 |