Honda Power Equipment EM1600X, EM1800X, EM2200X owner manual DC Circuit Breaker

Page 15

DC application

The DC terminals may be used for charging 12 volt automotive-type batteries only.

mBatteries produce explosive gases. Keep sparks, flames, and

cigarettes away. To prevent the possibility of creating a spark near the battery, connect charging cables first to the battery, then to the generator, and disconnect cables at the generator first.

CAUTION:

lDo not attempt to start an automobile engine while the generator is still

connected to the battery. The generator may be damaged.

lConnect the positive battery terminal to the positive generator terminal. Do not reverse the charging cables, or serious damage to the generator and/or battery may occur.

NOTE:

lThe DC terminals may be used while the AC power is in use.

lAn overloaded DC circuit will trip the DC circuit protector (push button

comes out). If this happens, wait a few minutes before pushing in the circuit protector to resume operation.

DC CIRCUIT BREAKER

POSITIVE TERMINAL (RED)

(BLACK)

13

Image 15
Contents Generator Page Page Contents Generator Safety Component Identification Fuel PRE-OPERATION Check Fuel Gauge Starting the Engine Page Engine Switch OIL Alert Lampe Generator USE Volt Meter AC Circuit Breaker Pilot Lamp DC Circuit Breaker Stopping the Engine Maintenance Maintenance Schedule OIL Filler OIL Drain Plug Reinstall the air cleaner element and the cover Rubber Gasket Filter CUP Plug Wrench Spark Plug CAP Page Protector Page TRANSPORTING/STORAGE Troubleshooting Defects WIR Light Blue Page Honda GX140 SpecificationsWarranty Service Memo Page Page 31ZB1010