8. TRANSPORTING/STORAGE

BWhen transporting the generator, turn the engine switch OFF and keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite.

Before storing the unit for an extended period:

1.Be sure the storage area is free of excessive humidity and dust.

2.Drain the fuel -

a.With the fuel valve OFF, remove and empty the filter cup.

b.Turn the fuel valve ON and drain the gasoline in the fuel tank into a suitable container.

c.Replace the filter cup and tighten securely.

d.Loosen the carburetor drain screw and drain the gasoline from the carburetor into a suitable container.

3.Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust

‘valves are closed. Storing the engine in this position will help to protect it from internal corrosion.

24

Image 26
Contents Generator Page Page Contents Generator Safety Component Identification Fuel PRE-OPERATION Check Fuel Gauge Starting the Engine Page Engine Switch OIL Alert Lampe Generator USE Volt Meter AC Circuit Breaker Pilot Lamp DC Circuit Breaker Stopping the Engine Maintenance Maintenance Schedule OIL Filler OIL Drain Plug Reinstall the air cleaner element and the cover Rubber Gasket Filter CUP Plug Wrench Spark Plug CAP Page Protector Page TRANSPORTING/STORAGE Troubleshooting Defects WIR Light Blue Page Specifications Honda GX140Warranty Service Memo Page Page 31ZB1010