Honda Power Equipment EM1800X, EM2200X, EM1600X owner manual Protector

Page 24

Spark arrester maintenance

mIf the generator has been running, the muffler will be.very hot. Allow it to cool before proceeding.

CAUTION: The spark arrester must be serviced every 100 hours to maintain its efficiency.

1. Loosen the five 6 mm bolts to remove the muffler protedtor.

PROTECTOR

bolts

2.Remove the two 8 mm bolts at the exhaust pipe and the 8 mm bolt at the muffler stay.

Remove the muffler and the spark arrester.

Two 8 mm bolts

MUFFLER

22

Image 24
Contents Generator Page Page Contents Generator Safety Component Identification Fuel PRE-OPERATION Check Fuel Gauge Starting the Engine Page Engine Switch OIL Alert Lampe Generator USE Volt Meter AC Circuit Breaker Pilot Lamp DC Circuit Breaker Stopping the Engine Maintenance Maintenance Schedule OIL Filler OIL Drain Plug Reinstall the air cleaner element and the cover Rubber Gasket Filter CUP Plug Wrench Spark Plug CAP Page Protector Page TRANSPORTING/STORAGE Troubleshooting Defects WIR Light Blue Page Specifications Honda GX140Warranty Service Memo Page Page 31ZB1010