(Model No. 004373-3) Guardian Liquid-cooled 40 kW Generator

Control Panel 4.3L – Drawing No. 0D4995-C

ITEM

PART NO.

QTY.

DESCRIPTION

 

ITEM

PART NO.

QTY.

DESCRIPTION

1

0D1523

1

PANEL BTM & BACK CONTROL

31

070045

1

AMMETER AC 0-200

 

 

 

PANEL

32

070042

1

FREQUENCY METER 240V 55-65HZ

2

0D1521A

1

CONTROL PANEL, FRONT W/ SILK

33

081988

1

DECAL EXERCISE INFO

 

 

 

SCREEN

34

0C1229

1

DECAL CUST CONN BOX

3

0D1522

2

PANEL,SIDE COVER CONTROL

35

098647

1

ASSY L.C. ELECT GOV

 

 

 

PANEL

36

0A3968

1

CAPACITOR FILTER ASY

4

067680

1

ASSY VOLTAGE REGULATOR 60HZ

37

048766

REF

BLOCK TERM 20A 2 X 6 X 1100V

5

0C8243

1

WASHER LOCK HDPDEUTSCH

39

083264

1

TFMR ASM,CMA 240/12V

6

0C8244

1

NUT, HDP DEUTSCH

41

057335

REF

BLOCK TERM 20A 20 X 6 X 1100V

8

048467

1

CIRCT BRK 7 X 1 ETA 46-500-P

42

076061

1

DECAL, TERM. STRIP

9

057907

1

RES WW LUG 10R 10% 25W

43

029333

6

TIE WRAP 7.4" X .19" NATL UL

10

064008

1

COVER CON PNL TOP (NOT SHOWN)

45

040479

4

VIB MNT 1.0 X 1.0 X 1/4-20

12

055444

1

HEATSINK

46

022507

4

SCREW HHC 1/4-20 X 1/2 G5

13

030468

1

WASHER STEP NYLON .20

47

022127

4

NUT HEX 1/4-20 STEEL

14

049939

1

RECTIFIER MSC 12A 600V 1N1206R

48

022097

4

WASHER LOCK M6-1/4

15

070370

1

WASHER MICA .203

49

033121

14

SCREW HHC #10-32 X 1/2

16

022158

1

NUT HEX #10-32 STEEL

50

022152

14

WASHER LOCK #10

17

023762

1

WASHER SHAKEPROOF EXT #10

51

036902

4

SCREW PPHM #6-32 X 1/2

 

 

 

STL

52

022155

6

WASHER LOCK #6

18

023897

15

WASHER FLAT #10 ZINC

53

022985

8

WASHER FLAT #6 ZINC

19

076009A

1

PP LOGIC ASM 50/60HZ

54

036918

8

SCREW PPHM #8-32 X 1/2

20

040213

4

PCB SUPPORT SNAP-IN 1/4"

55

022264

8

WASHER LOCK M4

21

027744

1

GROMMET 3/4 X 5/32 X 5/16

56

038150

8

WASHER FLAT #8 ZINC

22

082573

1

SWITCH ROCKER DPST 125V SPD

57

022471

8

NUT HEX #8-32 STEEL

23

076020

1

SWITCH TOG DPDT 15/10 SP

58

022188

6

NUT HEX #6-32 STEEL

24

032300

1

HOLDER FUSE

59

036908

2

SCREW PPHM #6-32 X 1-1/4

25

022676

1

FUSE 15A X AGC15

60

0C2428

4

SCREW PHTT #6-32 X 1/2 ZYC

26

064009

1

LIGHT 12VDC .02A LED RED PILOT

61

0C2323

4

SCREW PHTT #6-32 X 5/8 ZYC

27

061945

1

SWITCH SELECTOR 6A AMP/V

62*

0D5324

1

FUSE & HOLDER LITTEL 7.5A

28

076037

1

VOLTMETER DC 8-18V

63*

0A9611

REF.

FUSE 7.5AXBK/AGC7.5NX W/22670

29

070081

1

HOURMETER

 

 

 

 

 

30

070043

1

VOLTMETER AC 0-300

 

* PART OF CONTROL PANEL WIRE HARNESS

Generac® Power Systems, Inc. 35

Image 37
Contents Liquid-cooled, Prepackaged Standby Generators Authorized Dealer Location IntroductionIntroduction Inside Front Cover General Hazards Electrical Hazards UNPACKING/INSPECTION Prepackaged Transfer SwitchGenerator Generator AC Connection SystemsMain Circuit Breaker SpecificationsEngine Protective Devices ‹ 1.9.1 Conversion to LP GAS Vapor Fuel Requirements RecommendationsCoolant Emissions Control System‹ 1.12.1 AIR Fuel Ratio Controller Basic Standby Electric System Standby Generator InstallationNfpa Standards Other Published Standards‹ 2.6.1 PRE-PACKAGED Type Switch Transfer Switch Start Signal ConnectionsMethod Grounding the GeneratorPreparation Before START-UP Battery Installation‹ 2.7.1 Vented Batteries ‹ 2.8.1 Prior to Initial START-UP ‹ 2.8.2 Transfer SwitchUsing the AUTO/OFF/MANUAL Switch Engine Heater Sequence of Automatic Operation‹ 3.2.3 Manual Position Checking the Engine OIL Level Weekly Exercise Cycle‹ 4.2.2 OIL and Filter Change Procedure Changing the Engine AIR CleanerChanging the Engine OIL and Filter ‹ 4.2.1 Engine OIL Recommendations‹ 4.5.1 Battery Replacement Battery MaintenanceSpark Plugs Cooling System Miscellaneous MaintenanceOverload Protection for DC Fuse‹ 4.11.1 Removal from Service OUT of Service Procedure‹ 4.11.2 Return to Service SYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideElectrical Data Not Used on Guardian Unit Electrical Data TS1 Generator D4992-A Model No Section 40 kW 0D6974 KW Generators No D6975 27 *28 Drain Pan To Oil On Oil QTY Description Base Frame Assembly M6 Hinge Panel Face Panel BTM & Back Control VDC Panel Face Cover Plate AVR ALT Leads Sensing Wire QTY Flywheel Engine Stator Leads Detail Scroll Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists MOUNT, Engine R & L To Thermostat Housing To Engine Block To Starter Solenoid RED Black To Engine Block Part KIT Radiator Copper Brass DIA. Clamp ASSEMBLY2 Compartment NUT Wing 1/4-20 Nylk To Stepper Motor Support Solenoid NAT GAS Attach to REGULATOR, N/G R600S Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper Guardian Liquid-cooled 40 kW Generators MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyThis Warranty Shall not Apply to the Following Warranty Schedule

004373-3, 004626-2, 004373-3 , 004626-2 specifications

Generac is a leader in the power generation industry, known for its reliable and innovative products. Among its extensive range of offerings, two models stand out: the Generac 004373-3 and the 004626-2. These models represent the cutting edge of home standby generators.

The Generac 004373-3 is designed to provide seamless power during outages, ensuring that homes remain comfortable and functional. One of its main features is the automatic transfer switch, which detects a power outage and activates the generator within seconds. This automatic response eliminates the need for manual intervention, allowing homeowners to go about their lives without interruption.

This model is equipped with a durable engine that runs on liquid propane or natural gas, providing flexibility depending on the availability of fuel sources. The 004373-3 has an impressive power output, capable of powering essential household appliances, including refrigerators, heating systems, and lights. Its compact design allows for easy installation, making it suitable for a variety of home sizes.

On the other hand, the Generac 004626-2 also focuses on providing reliable power but with additional advanced features. One of its key characteristics is the True Power Technology, which delivers clean and stable power, making it ideal for sensitive electronics and appliances. This feature is crucial for households that rely on digital devices, protecting them from fluctuations that could potentially cause damage.

Additionally, the 004626-2 comes with a user-friendly control panel that allows for easy monitoring and adjustments. The model also incorporates Smart Management Technology, which enables users to manage their power consumption effectively. This technology allows homeowners to prioritize the most critical circuits, ensuring essential services remain operational during outages.

Both models emphasize ease of maintenance, with a design that facilitates access to components for servicing. Generac generators are known for meeting high standards of quality, ensuring reliability and longevity. With their advanced technologies and robust features, the Generac 004373-3 and 004626-2 provide peace of mind, allowing homeowners to remain connected and powered, no matter the circumstances. Whether for unexpected outages or planned maintenance, Generac continues to set the standard in home power solutions.