Generac 004373-3, 004626-2, 004373-3 , 004626-2 owner manual Electrical Hazards

Page 5

Important Safety Instructions

Guardian Liquid-cooled 40 kW Generator

Inspect the generator regularly, and promptly repair or replace all worn, damaged or defective parts using only factory-approved parts.

Before performing any maintenance on the generator, disconnect its battery cables to prevent accidental start-up. Disconnect the cable from the battery post indicated by a NEGATIVE, NEG or (–) first. Reconnect that cable last.

Never use the generator or any of its parts as a step. Stepping on the unit can stress and break parts, and may result in dangerous operating conditions from leaking exhaust gases, fuel leakage, oil leakage, etc.

ELECTRICAL HAZARDS

All generators covered by this manual produce dan- gerous electrical voltages and can cause fatal electri- cal shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in operation. Avoid con- tact with bare wires, terminals, connections, etc., while the unit is running. Ensure all appropriate cov- ers, guards and barriers are in place before operating the generator. If work must be done around an oper- ating unit, stand on an insulated, dry surface to reduce shock hazard.

Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT.

If people must stand on metal or concrete while installing, operating, servicing, adjusting or repairing this equipment, place insulative mats over a dry wooden platform. Work on the equipment only while standing on such insulative mats.

The National Electrical Code (NEC) requires the frame and external electrically conductive parts of the generator to be connected to an approved earth ground and/or grounding rods. This grounding will help prevent dangerous electrical shock that might be caused by a ground fault condition in the generator set or by static electricity. Never disconnect the ground wire.

Wire gauge sizes of electrical wiring, cables and cord sets must be adequate to handle the maximum elec- trical current (ampacity) to which they will be sub- jected to.

Before installing or servicing this (and related) equip- ment, make sure that all power voltage supplies are positively turned off at their source. Failure to do so will result in hazardous and possibly fatal electrical shock.

Connecting this unit to an electrical system normally supplied by an electric utility shall be by means of a transfer switch so as to isolate the genrator electric system from the utility electric system while in oper- ation. Failure to isolate the two electric system power sources from each other by such means will result in damage to the generator and may also result in injury or death to utility power workers due to backfeed of electrical energy.

Generators installed with an automatically transfer switch will crank and start automatically when nor- mal (utility) source voltage is removed or is below an acceptable preset level. To prevent such automatic start-up and possible injury to personnel, disable the generator’s automatic start circuit (battery cables, etc.) before working on or around the unit. Then, place a “Do Not Operate” tag on the generator control panel and on the transfer switch.

In case of accident caused by electric shock, immedi- ately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting implement, such as a rope or board, to free the victim from the live con- ductor. If the victim is unconscious, apply first aid and get immediate medical help.

Never wear jewelry when working on this equipment. Jewelry can conduct electricity resulting in electric shock, or may get caught in moving components causing injury.

FIRE HAZARDS

Keep a fire extinguisher near the generator at all times. DO NOT use any carbon tetra-chloride type extinguisher. Its fumes are toxic, and the liquid can deteriorate wiring insulation. Keep the extinguisher properly charged and be familiar with its use. If there are any questions pertaining to fire extinguishers, consult the local fire department.

EXPLOSION HAZARDS

Properly ventilate any room or building housing the generator to prevent build-up of explosive gas.

Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no combustible materials are left in the generator compartment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surrounding the generator clean and free from debris.

Generac generator sets may operate using one of sev- eral types of fuels. All fuel types are potentially FLAM- MABLE and/orEXPLOSIVE and should be handled with care. Comply with all laws regulating the stor- age and handling of fuels. Inspect the unit’s fuel sys- tem frequently and correct any leaks immediately. uel supply lines must be properly installed, purged and leak tested according to applicable fuel-gas codes before placing this equipment into service.

Diesel fuels are highly FLAMMABLE. Gaseous fluids such as natural gas and liquid propane (LP) gas are extremely EXPLOSIVE. Natural gas is lighter than air, and LP gas is heavier than air; install leak detectors accordingly.

Generac® Power Systems, Inc. 3

Image 5
Contents Liquid-cooled, Prepackaged Standby Generators Authorized Dealer Location IntroductionIntroduction Inside Front Cover General Hazards Electrical Hazards UNPACKING/INSPECTION Prepackaged Transfer SwitchGenerator Generator AC Connection SystemsEngine Protective Devices SpecificationsMain Circuit Breaker ‹ 1.9.1 Conversion to LP GAS Vapor Fuel Requirements Recommendations‹ 1.12.1 AIR Fuel Ratio Controller Emissions Control SystemCoolant Basic Standby Electric System Standby Generator InstallationNfpa Standards Other Published Standards‹ 2.6.1 PRE-PACKAGED Type Switch Transfer Switch Start Signal ConnectionsMethod Grounding the Generator‹ 2.7.1 Vented Batteries Battery InstallationPreparation Before START-UP ‹ 2.8.1 Prior to Initial START-UP ‹ 2.8.2 Transfer SwitchUsing the AUTO/OFF/MANUAL Switch ‹ 3.2.3 Manual Position Sequence of Automatic OperationEngine Heater Checking the Engine OIL Level Weekly Exercise Cycle‹ 4.2.2 OIL and Filter Change Procedure Changing the Engine AIR CleanerChanging the Engine OIL and Filter ‹ 4.2.1 Engine OIL RecommendationsSpark Plugs Battery Maintenance‹ 4.5.1 Battery Replacement Cooling System Miscellaneous MaintenanceOverload Protection for DC Fuse‹ 4.11.2 Return to Service OUT of Service Procedure‹ 4.11.1 Removal from Service SYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideElectrical Data Not Used on Guardian Unit Electrical Data TS1 Generator D4992-A Model No Section 40 kW 0D6974 KW Generators No D6975 27 *28 Drain Pan To Oil On Oil QTY Description Base Frame Assembly M6 Hinge Panel Face Panel BTM & Back Control VDC Panel Face Cover Plate AVR ALT Leads Sensing Wire QTY Flywheel Engine Stator Leads Detail Scroll Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists MOUNT, Engine R & L To Thermostat Housing To Engine Block To Starter Solenoid RED Black To Engine Block Part KIT Radiator Copper Brass DIA. Clamp ASSEMBLY2 Compartment NUT Wing 1/4-20 Nylk To Stepper Motor Support Solenoid NAT GAS Attach to REGULATOR, N/G R600S Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper Guardian Liquid-cooled 40 kW Generators PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyThis Warranty Shall not Apply to the Following Warranty Schedule

004373-3, 004626-2, 004373-3 , 004626-2 specifications

Generac is a leader in the power generation industry, known for its reliable and innovative products. Among its extensive range of offerings, two models stand out: the Generac 004373-3 and the 004626-2. These models represent the cutting edge of home standby generators.

The Generac 004373-3 is designed to provide seamless power during outages, ensuring that homes remain comfortable and functional. One of its main features is the automatic transfer switch, which detects a power outage and activates the generator within seconds. This automatic response eliminates the need for manual intervention, allowing homeowners to go about their lives without interruption.

This model is equipped with a durable engine that runs on liquid propane or natural gas, providing flexibility depending on the availability of fuel sources. The 004373-3 has an impressive power output, capable of powering essential household appliances, including refrigerators, heating systems, and lights. Its compact design allows for easy installation, making it suitable for a variety of home sizes.

On the other hand, the Generac 004626-2 also focuses on providing reliable power but with additional advanced features. One of its key characteristics is the True Power Technology, which delivers clean and stable power, making it ideal for sensitive electronics and appliances. This feature is crucial for households that rely on digital devices, protecting them from fluctuations that could potentially cause damage.

Additionally, the 004626-2 comes with a user-friendly control panel that allows for easy monitoring and adjustments. The model also incorporates Smart Management Technology, which enables users to manage their power consumption effectively. This technology allows homeowners to prioritize the most critical circuits, ensuring essential services remain operational during outages.

Both models emphasize ease of maintenance, with a design that facilitates access to components for servicing. Generac generators are known for meeting high standards of quality, ensuring reliability and longevity. With their advanced technologies and robust features, the Generac 004373-3 and 004626-2 provide peace of mind, allowing homeowners to remain connected and powered, no matter the circumstances. Whether for unexpected outages or planned maintenance, Generac continues to set the standard in home power solutions.