Generac 004373-3 , 004626-2, 004373-3, 004626-2 owner manual To Stepper Motor

Page 54

Section 7 — Exploded Views and Parts Lists

(Model No. 004373-3) Guardian Liquid-cooled 40 kW Generators 4.3L Nat. Gas Fuel System – Drawing No. 0E0714

18

17

19 6

7

18

25

TO STEPPER MOTOR

 

17

 

40

24 2

39

28

29

30

3

3 3 1

34

13

12

13

11

12

11

 

 

13

 

 

12

 

 

11

2

 

 

24

9

 

 

8

10

6

5

 

 

24

 

 

 

 

 

1

4

 

 

 

 

24

 

 

 

 

2

3

2

20

37

 

 

 

21

TO VALVE COVER

 

 

 

42

 

 

 

TO INTAKE

MANIFOLD

38

 

 

 

 

 

23

14

27

16

 

 

15

35

36

52 Generac® Power Systems, Inc.

Image 54
Contents Liquid-cooled, Prepackaged Standby Generators Introduction Authorized Dealer LocationIntroduction Inside Front Cover General Hazards Electrical Hazards Generator Prepackaged Transfer SwitchUNPACKING/INSPECTION Generator AC Connection SystemsSpecifications Main Circuit BreakerEngine Protective Devices Fuel Requirements Recommendations ‹ 1.9.1 Conversion to LP GAS VaporEmissions Control System Coolant‹ 1.12.1 AIR Fuel Ratio Controller Nfpa Standards Standby Generator InstallationBasic Standby Electric System Other Published StandardsMethod Transfer Switch Start Signal Connections‹ 2.6.1 PRE-PACKAGED Type Switch Grounding the GeneratorBattery Installation Preparation Before START-UP‹ 2.7.1 Vented Batteries ‹ 2.8.2 Transfer Switch ‹ 2.8.1 Prior to Initial START-UPUsing the AUTO/OFF/MANUAL Switch Sequence of Automatic Operation Engine Heater‹ 3.2.3 Manual Position Weekly Exercise Cycle Checking the Engine OIL LevelChanging the Engine OIL and Filter Changing the Engine AIR Cleaner‹ 4.2.2 OIL and Filter Change Procedure ‹ 4.2.1 Engine OIL RecommendationsBattery Maintenance ‹ 4.5.1 Battery ReplacementSpark Plugs Overload Protection for Miscellaneous MaintenanceCooling System DC FuseOUT of Service Procedure ‹ 4.11.1 Removal from Service‹ 4.11.2 Return to Service Service Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionElectrical Data Not Used on Guardian Unit Electrical Data TS1 Generator D4992-A Model No Section 40 kW 0D6974 KW Generators No D6975 27 *28 Drain Pan To Oil On Oil QTY Description Base Frame Assembly M6 Hinge Panel Face Panel BTM & Back Control VDC Panel Face Cover Plate AVR ALT Leads Sensing Wire QTY Flywheel Engine Stator Leads Detail Scroll Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists MOUNT, Engine R & L To Thermostat Housing To Engine Block To Starter Solenoid RED Black To Engine Block Part KIT Radiator Copper Brass DIA. Clamp ASSEMBLY2 Compartment NUT Wing 1/4-20 Nylk To Stepper Motor Support Solenoid NAT GAS Attach to REGULATOR, N/G R600S Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper Guardian Liquid-cooled 40 kW Generators Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule This Warranty Shall not Apply to the Following

004373-3, 004626-2, 004373-3 , 004626-2 specifications

Generac is a leader in the power generation industry, known for its reliable and innovative products. Among its extensive range of offerings, two models stand out: the Generac 004373-3 and the 004626-2. These models represent the cutting edge of home standby generators.

The Generac 004373-3 is designed to provide seamless power during outages, ensuring that homes remain comfortable and functional. One of its main features is the automatic transfer switch, which detects a power outage and activates the generator within seconds. This automatic response eliminates the need for manual intervention, allowing homeowners to go about their lives without interruption.

This model is equipped with a durable engine that runs on liquid propane or natural gas, providing flexibility depending on the availability of fuel sources. The 004373-3 has an impressive power output, capable of powering essential household appliances, including refrigerators, heating systems, and lights. Its compact design allows for easy installation, making it suitable for a variety of home sizes.

On the other hand, the Generac 004626-2 also focuses on providing reliable power but with additional advanced features. One of its key characteristics is the True Power Technology, which delivers clean and stable power, making it ideal for sensitive electronics and appliances. This feature is crucial for households that rely on digital devices, protecting them from fluctuations that could potentially cause damage.

Additionally, the 004626-2 comes with a user-friendly control panel that allows for easy monitoring and adjustments. The model also incorporates Smart Management Technology, which enables users to manage their power consumption effectively. This technology allows homeowners to prioritize the most critical circuits, ensuring essential services remain operational during outages.

Both models emphasize ease of maintenance, with a design that facilitates access to components for servicing. Generac generators are known for meeting high standards of quality, ensuring reliability and longevity. With their advanced technologies and robust features, the Generac 004373-3 and 004626-2 provide peace of mind, allowing homeowners to remain connected and powered, no matter the circumstances. Whether for unexpected outages or planned maintenance, Generac continues to set the standard in home power solutions.