9.Apply thread sealant to the threads of the hose fit- ting and replace it into the regulator body.

10.Re-attach the small hose and hose clamp and tighten as necessary.

11.Replace the engine air in baffle using the four M6 screws.

12.Identify both brass adjustment screws on the reg- ulator.

NOTE:

One adjustment screw can be accessed from the front of the unit and the second can be accessed from the back of the unit enclosure by removing the plastic hole plug. The screw can be turned with a long flat blade screwdriver.

13.To adjust the system to run on LP fuel, turn BOTH adjuster screws 1/2 TURN CLOCKWISE. The system should now be set for maximum power and best perfomance. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE SET PINS FROM THE REGULATOR HOUSING. THIS WILL VOID THE WARRANTY.

14.It may be necessary to make minor adjustments to the preset adjustment screw settings to achieve maximum power, particularly at higher altitudes. If experiencing problems with the unit producing maximum power, follow the procedure in Section 2.6 (Adjusting the Fuel Regulator).

1.10 LOCATION

1.10.1 GENERATOR

Install the generator set, in its protective enclosure, outdoors, where adequate cooling and ventilating air is always available. Consider these factors:

Install the unit where air inlet and outlet openings will not become obstructed by leaves, grass, snow, etc. If prevailing winds will cause blowing or drift- ing, consider using a windbreak to protect the unit.

Install the generator on high ground where water levels will not rise and endanger it.

Allow sufficient room on all sides of the generator for maintenance and servicing. A good rule is to allow three feet of space on all sides.

Where strong prevailing winds blow from one direction, face the generator air inlet openings to the prevailing winds.

Install the generator as close as possible to the fuel supply, to reduce the length of piping.

Install the generator as close as possible to the transfer switch. HOWEVER, REMEMBER THAT LAWS OR CODES MAY REGULATE THE DIS- TANCE.

1.10.2 TRANSFER SWITCH

The transfer switch shipped with this generator is rated 100 amps maximum at 120/240 volts AC single phase. The enclosure of the transfer switch is NEMA

1.This type of enclosure is intended for indoor use only. Follow these rules:

Install the transfer switch indoors on a firm, stur- dy supporting structure.

To prevent switch distortion, level the switch if nec- essary. This can be done by placing washers between the switch enclosure and mounting surface.

Never install the switch where water or any corro- sive substance might drip onto the enclosure.

Protect the switch at all times against excessive moisture, dust, dirt, lint, construction grit and cor- rosive vapors.

1.11 BATTERY INSTALLATION

Fill the battery with the proper electrolyte fluid if nec- essary and have the battery fully charged before installing it.

Before installing and connecting the battery, complete the following steps:

1.Set the generator's AUTO/OFF/MANUAL switch to OFF.

2.Turn off utility power supply to the transfer switch.

DANGER

If the AUTO/OFF/MANUAL switch is not set to its OFF position, the generator can crank and start as soon as the battery cables are connect- ed. If the utility power supply is not turned off, sparking can occur at the battery posts and cause an explosion.

Battery cables were factory connected at the genera- tor (Figure 1.5). Connect cables to battery posts as follows:

3.Connect the red battery cable (from starter con- tactor) to the battery post indicated by a positive, POS or (+).

4.Connect the black battery cable (from frame ground) to the battery post indicated by a nega- tive, NEG or (—).

NOTE:

Damage will result if battery connections are made in reverse.

8 Generac® Power Systems, Inc.

Image 10
Contents Centurion Introduction Authorized Dealer LocationTroubleshooting General Hazards Electrical Hazards ‹ Standards IndexBreaker for Bedrooms UNPACKING/INSPECTIONProtection Systems Generator 8.5 kW, V-Twin GT-990/760 EngineSpecifications ‹ 1.5.1 GeneratorFuel Requirements Recommendations Reconfiguring Fuel SystemSystem SET LED Fuel ConsumptionTransfer Switch Battery InstallationLocation Battery Battery Cable ConnectionsBefore Initial START-UP Check Transfer Switch OperationElectrical Checks Generator Tests Under Load Adjusting the Regulator Natural GAS onlyChecking Automatic Operation Engine Governor Adjustment Set PinBREAK-IN Procedure Voltage Regulator Adjustment‹ 3.2.1 Auto Position Manual Transfer Operation Automatic Transfer OperationSequence of Automatic Operation ‹ 3.2.3 Manual PositionSetting the Exercise Timer ‹ 3.5.2 Transfer Back to Utility Power SourceChecking the Engine OIL Level ‹ 3.7.1 LOW OIL Pressure Switch‹ 3.7.2 High Temperature Switch ‹ 3.7.4 OverspeedChanging the OIL Filter ‹ 4.3.2 OIL Change ProcedureChanging the Engine OIL ‹ 4.3.1 Engine OIL RecommendationsBattery Maintenance Spark PlugsAdjusting Valve Clearance Cooling System‹ 4.11.1 Removal from Service OUT of Service Procedure‹ 4.11.2 Return to Service Corrosion ProtectionService Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionMounting Dimensions Electrical Data Customer Battery Utility ATS YLW Electrical Data Electrical Data Air-cooled 8.5 kW Generator Enclosure Drawing No F0100-A Part NO. QTY Description Exploded Views and Parts Lists QTY Description 140 With Sleeve Exploded Views and Parts Lists Part NO. QTY. Description Exploded Views and Parts Lists SWITCH, Spst ON-ON N/O Exploded Views and Parts Lists BOX GTS Load Center Air-cooled 8.5 kW Generator Regulator Drawing No D8720-D CASTING, Twin Regulator Housing Air-cooled 8.5 kW Generator Air-cooled 8.5 kW Generator MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule

004692-2 specifications

The Generac 004692-2 is a reliable and efficient portable generator designed to provide power when and where it’s needed most. Ideal for both residential use and outdoor activities, this generator has become a popular choice for homeowners and outdoor enthusiasts alike.

One of the standout features of the Generac 004692-2 is its power output. It offers a robust wattage capacity, allowing users to run essential appliances during a power outage, or to provide electricity for tools and equipment while camping or during a construction project. Its powerful engine is engineered for durability, ensuring longevity and consistent performance.

Another important aspect of the 004692-2 is its portability. Designed with an ergonomic handle and sturdy wheels, this generator is easy to transport, whether moving it around the yard or taking it on the go for outdoor adventures. Its compact design allows for easy storage, making it a convenient addition to any household.

The Generac 004692-2 incorporates advanced technologies for ease of use and efficiency. It features a user-friendly control panel that includes multiple outlets, allowing users to connect various devices simultaneously. The generator is equipped with a low-oil automatic shutdown system that helps protect the engine from damage, extending the life of the generator.

Moreover, the generator is designed with a quiet operation feature, making it suitable for residential areas. This means users can rely on it for power without disturbing neighbors during critical times such as family gatherings or late-night emergencies.

In terms of fuel efficiency, the Generac 004692-2 performs admirably with its optimized engine design, allowing users to maximize run time while minimizing fuel consumption. This feature is not only cost-effective but also environmentally friendly, reducing the carbon footprint during usage.

Safety is paramount with any generator, and the Generac 004692-2 includes several built-in safety features. The generator is designed to withstand various weather conditions, ensuring reliability during storms or outdoor events. Additionally, the generator's design includes features that reduce the risk of accidental starting, adding an extra layer of protection for the user.

In conclusion, the Generac 004692-2 stands out as an excellent choice for those seeking a dependable portable generator. Its combination of powerful performance, portability, user-friendly design, and built-in safety features makes it an ideal solution for a variety of power needs. Whether for home backup or outdoor use, this generator provides peace of mind with its reliability and efficiency.