Generac 004692-2 owner manual Battery Cable Connections

Page 11

Section 1 — General Information

Air-cooled 8.5 kW Generator

Figure 1.5 – Battery Cable Connections

NOTE:

The generator is equipped with a battery trickle charger that is active when the unit is set up for automatic operation. With the battery installed and utility power source voltage available to the transfer switch, the battery receives a trickle charge while the engine is not running, to prevent self-discharge. The trickle charger is designed to help extend the life of the battery by maintaining the battery when the unit is not running. The trickle charge feature cannot be used to recharge a discharged battery.

1.12 THE BATTERY

Servicing of the battery is to be performed or super- vised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized person- nel away from batteries.

When replacing the battery, use the following type of battery: Group 26/26R 12VDC, 525 cold-cranking amps for 8.5 kW at -17.8º C (0º F) minimum. When using a maintenance-free battery, it is not necessary to check the specific gravity or electrolyte level. Have these procedures performed at the intervals specified in the “Service Schedule.” A negative ground system is used. Battery connections are shown on the wiring diagrams. Make sure the battery is correctly connect- ed and terminals are tight. Observe battery polarity when connecting the battery to the generator set.

Remove watches, rings or other metal objects;

Use tools with insulated handles;

Wear rubber gloves and boots;

Do not lay tools or metal parts on top of the battery; and

Disconnect charging source prior to connecting or dis- connecting battery terminals.

Do not open or mutilate the battery. Released

!electrolyte has been known to be harmful to the skin and eyes, and to be toxic.

The electrolyte is a dilute sulfuric acid that is

!harmful to the skin and eyes. It is electrically conductive and corrosive. The following procedures are to be observed:

Wear full eye protection and protective clothing;

Where electrolyte contacts the skin, wash it off immediately with water;

Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention; and

Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of 1 pound (500 grams) bicarbonate of soda to 1 gallon (4 liters) or water. The bicar- bonate of soda solution is to be added until the evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried.

Lead-acid batteries present a risk of fire because they generate hydrogen gas. The following procedures are to be followed:

DO NOT SMOKE when near the battery;

DO NOT cause flame or spark in battery area; and

Discharge static electricity from body before touch- ing the battery by first touching a grounded metal surface.

Be sure the AUTO/OFF/MANUAL switch is set to ! the OFF position before connecting the battery cables. If the switch is set to AUTO or MANUAL,

the generator can crank and start as soon as the battery cables are connected.

Be sure the utility power supply is turned off, or sparking may occur at the battery posts as the cables are attached and cause an explosion.

DANGER

Do not dispose of the battery in a fire. The battery is capable of exploding.

A battery presents a risk of electrical shock and high short circuit current. The following precautions are to be observed when working on batteries:

Generac® Power Systems, Inc. 9

Image 11
Contents Centurion Authorized Dealer Location IntroductionTroubleshooting General Hazards ‹ Standards Index Electrical HazardsProtection Systems UNPACKING/INSPECTIONBreaker for Bedrooms 8.5 kW, V-Twin GT-990/760 Engine Generator‹ 1.5.1 Generator SpecificationsFuel Consumption Reconfiguring Fuel SystemSystem SET LED Fuel Requirements RecommendationsLocation Battery InstallationTransfer Switch Battery Cable Connections BatteryElectrical Checks Check Transfer Switch OperationBefore Initial START-UP Checking Automatic Operation Adjusting the Regulator Natural GAS onlyGenerator Tests Under Load Set Pin Engine Governor Adjustment‹ 3.2.1 Auto Position Voltage Regulator AdjustmentBREAK-IN Procedure ‹ 3.2.3 Manual Position Automatic Transfer OperationSequence of Automatic Operation Manual Transfer Operation‹ 3.5.2 Transfer Back to Utility Power Source Setting the Exercise Timer‹ 3.7.4 Overspeed ‹ 3.7.1 LOW OIL Pressure Switch‹ 3.7.2 High Temperature Switch Checking the Engine OIL Level‹ 4.3.1 Engine OIL Recommendations ‹ 4.3.2 OIL Change ProcedureChanging the Engine OIL Changing the OIL FilterSpark Plugs Battery MaintenanceCooling System Adjusting Valve ClearanceCorrosion Protection OUT of Service Procedure‹ 4.11.2 Return to Service ‹ 4.11.1 Removal from ServiceSYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideMounting Dimensions Electrical Data Customer Battery Utility ATS YLW Electrical Data Electrical Data Air-cooled 8.5 kW Generator Enclosure Drawing No F0100-A Part NO. QTY Description Exploded Views and Parts Lists QTY Description 140 With Sleeve Exploded Views and Parts Lists Part NO. QTY. Description Exploded Views and Parts Lists SWITCH, Spst ON-ON N/O Exploded Views and Parts Lists BOX GTS Load Center Air-cooled 8.5 kW Generator Regulator Drawing No D8720-D CASTING, Twin Regulator Housing Air-cooled 8.5 kW Generator Air-cooled 8.5 kW Generator PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule

004692-2 specifications

The Generac 004692-2 is a reliable and efficient portable generator designed to provide power when and where it’s needed most. Ideal for both residential use and outdoor activities, this generator has become a popular choice for homeowners and outdoor enthusiasts alike.

One of the standout features of the Generac 004692-2 is its power output. It offers a robust wattage capacity, allowing users to run essential appliances during a power outage, or to provide electricity for tools and equipment while camping or during a construction project. Its powerful engine is engineered for durability, ensuring longevity and consistent performance.

Another important aspect of the 004692-2 is its portability. Designed with an ergonomic handle and sturdy wheels, this generator is easy to transport, whether moving it around the yard or taking it on the go for outdoor adventures. Its compact design allows for easy storage, making it a convenient addition to any household.

The Generac 004692-2 incorporates advanced technologies for ease of use and efficiency. It features a user-friendly control panel that includes multiple outlets, allowing users to connect various devices simultaneously. The generator is equipped with a low-oil automatic shutdown system that helps protect the engine from damage, extending the life of the generator.

Moreover, the generator is designed with a quiet operation feature, making it suitable for residential areas. This means users can rely on it for power without disturbing neighbors during critical times such as family gatherings or late-night emergencies.

In terms of fuel efficiency, the Generac 004692-2 performs admirably with its optimized engine design, allowing users to maximize run time while minimizing fuel consumption. This feature is not only cost-effective but also environmentally friendly, reducing the carbon footprint during usage.

Safety is paramount with any generator, and the Generac 004692-2 includes several built-in safety features. The generator is designed to withstand various weather conditions, ensuring reliability during storms or outdoor events. Additionally, the generator's design includes features that reduce the risk of accidental starting, adding an extra layer of protection for the user.

In conclusion, the Generac 004692-2 stands out as an excellent choice for those seeking a dependable portable generator. Its combination of powerful performance, portability, user-friendly design, and built-in safety features makes it an ideal solution for a variety of power needs. Whether for home backup or outdoor use, this generator provides peace of mind with its reliability and efficiency.