Generac 004692-2 OUT of Service Procedure, Corrosion Protection, ‹ 4.11.2 Return to Service

Page 22

Section 4 — Maintenance

Air-cooled 8.5 kW Generator

4.10 ATTENTION AFTER SUBMERSION

‹ 4.11.2 RETURN TO SERVICE

If the generator has been submerged in water, it must not be started and operated. Following any submersion in water, have a Generac Authorized Dealer thoroughly clean and dry the generator.

4.11 OUT OF SERVICE PROCEDURE

‹4.11.1 REMOVAL FROM SERVICE

If the generator cannot be exercised every seven days, and it is to be out of service longer than 90 days, pre- pare the generator for storage as follows:

1.Start the engine and let it warm up.

2.Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down.

3.Once the unit has shut down, it will signal a low oil fault.

4.Set the AUTO/OFF/MANUAL switch to OFF and turn off the utility power to the transfer switch.

5.While the engine is still warm from running, drain the oil completely. Refill the crankcase with oil. See ”Engine Oil Recommendations,” Section 4.3.1.

6.Attach a tag to the engine indicating the viscosity and classification of the oil in the crankcase.

7.Remove the spark plug(s) and spray fogging agent into the spark plug(s) threaded openings. Reinstall and tighten the spark plug(s).

8.Remove the battery and store it in a cool, dry room on a wooden board. Never store the battery on any concrete or earthen floor.

9.Clean and wipe the entire generator.

To return the unit to service after storage, proceed as follows:

1.Verify that utility power is turned off and that the AUTO/OFF/MANUAL switch is set to OFF.

2.Check the tag on the engine for oil viscosity and classification. Verify that the correct recommend- ed oil is used in the engine (see Section 4.3.1). If necessary, drain and refill with the proper oil.

3.Check the state of the battery. Fill all cells of unsealed batteries to the proper level with dis- tilled water. DO NOT USE TAP WATER IN THE BATTERY. Recharge the battery to 100 percent state of charge, or, if defective, replace the battery. See “Specifications,” Section 1.5, for type and size.

4.Clean and wipe the entire generator.

5.Reconnect the battery. Observe battery polarity. Damage may occur if the battery is connected incorrectly.

6.Open the fuel shutoff valve.

7.Start the unit by moving the AUTO/OFF/MANUAL switch to MANUAL. Allow the unit to warm up thoroughly.

8.Stop the unit and set the AUTO/OFF/MANUAL switch to AUTO.

9.Turn on the utility power to the transfer switch.

10.The generator is now ready for service.

NOTE:

If the battery was dead or disconnected, the exer- cise timer must be reset.

4.12 CORROSION PROTECTION

Periodically wash and wax the enclosure using auto- motive type products. Frequent washing is recom- mended in a salt water, coastal area. Spray engine linkages with a light oil such as WD-40.

20 Generac® Power Systems, Inc.

Image 22
Contents Centurion Introduction Authorized Dealer LocationTroubleshooting General Hazards Electrical Hazards ‹ Standards IndexBreaker for Bedrooms UNPACKING/INSPECTIONProtection Systems Generator 8.5 kW, V-Twin GT-990/760 EngineSpecifications ‹ 1.5.1 GeneratorFuel Requirements Recommendations Reconfiguring Fuel SystemSystem SET LED Fuel ConsumptionTransfer Switch Battery InstallationLocation Battery Battery Cable ConnectionsBefore Initial START-UP Check Transfer Switch OperationElectrical Checks Generator Tests Under Load Adjusting the Regulator Natural GAS onlyChecking Automatic Operation Engine Governor Adjustment Set PinBREAK-IN Procedure Voltage Regulator Adjustment‹ 3.2.1 Auto Position Manual Transfer Operation Automatic Transfer OperationSequence of Automatic Operation ‹ 3.2.3 Manual PositionSetting the Exercise Timer ‹ 3.5.2 Transfer Back to Utility Power SourceChecking the Engine OIL Level ‹ 3.7.1 LOW OIL Pressure Switch‹ 3.7.2 High Temperature Switch ‹ 3.7.4 OverspeedChanging the OIL Filter ‹ 4.3.2 OIL Change ProcedureChanging the Engine OIL ‹ 4.3.1 Engine OIL RecommendationsBattery Maintenance Spark PlugsAdjusting Valve Clearance Cooling System‹ 4.11.1 Removal from Service OUT of Service Procedure‹ 4.11.2 Return to Service Corrosion ProtectionService Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionMounting Dimensions Electrical Data Customer Battery Utility ATS YLW Electrical Data Electrical Data Air-cooled 8.5 kW Generator Enclosure Drawing No F0100-A Part NO. QTY Description Exploded Views and Parts Lists QTY Description 140 With Sleeve Exploded Views and Parts Lists Part NO. QTY. Description Exploded Views and Parts Lists SWITCH, Spst ON-ON N/O Exploded Views and Parts Lists BOX GTS Load Center Air-cooled 8.5 kW Generator Regulator Drawing No D8720-D CASTING, Twin Regulator Housing Air-cooled 8.5 kW Generator Air-cooled 8.5 kW Generator MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule

004692-2 specifications

The Generac 004692-2 is a reliable and efficient portable generator designed to provide power when and where it’s needed most. Ideal for both residential use and outdoor activities, this generator has become a popular choice for homeowners and outdoor enthusiasts alike.

One of the standout features of the Generac 004692-2 is its power output. It offers a robust wattage capacity, allowing users to run essential appliances during a power outage, or to provide electricity for tools and equipment while camping or during a construction project. Its powerful engine is engineered for durability, ensuring longevity and consistent performance.

Another important aspect of the 004692-2 is its portability. Designed with an ergonomic handle and sturdy wheels, this generator is easy to transport, whether moving it around the yard or taking it on the go for outdoor adventures. Its compact design allows for easy storage, making it a convenient addition to any household.

The Generac 004692-2 incorporates advanced technologies for ease of use and efficiency. It features a user-friendly control panel that includes multiple outlets, allowing users to connect various devices simultaneously. The generator is equipped with a low-oil automatic shutdown system that helps protect the engine from damage, extending the life of the generator.

Moreover, the generator is designed with a quiet operation feature, making it suitable for residential areas. This means users can rely on it for power without disturbing neighbors during critical times such as family gatherings or late-night emergencies.

In terms of fuel efficiency, the Generac 004692-2 performs admirably with its optimized engine design, allowing users to maximize run time while minimizing fuel consumption. This feature is not only cost-effective but also environmentally friendly, reducing the carbon footprint during usage.

Safety is paramount with any generator, and the Generac 004692-2 includes several built-in safety features. The generator is designed to withstand various weather conditions, ensuring reliability during storms or outdoor events. Additionally, the generator's design includes features that reduce the risk of accidental starting, adding an extra layer of protection for the user.

In conclusion, the Generac 004692-2 stands out as an excellent choice for those seeking a dependable portable generator. Its combination of powerful performance, portability, user-friendly design, and built-in safety features makes it an ideal solution for a variety of power needs. Whether for home backup or outdoor use, this generator provides peace of mind with its reliability and efficiency.