Carrier ASPASICCA015, ASPASICCA007, ASPASICCA012 Unpacking/Inspection, Protection Systems

Page 6

o • o

Section 1 -- General Information

GENERAL

Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators

NFORMATON

_Only qualified electricians or contractors should attempt such installations, which must comply

strictly with applicable codes, standards and regulations.

1.1UNPACKING/INSPECTION

After unpacking, carefully inspect the contents for damage.

This standby generator set has been factory supplied with a weather protective enclosure that is intended for outdoor installation only,

This UL listed standby generator set is packaged with an automatic transfer switch with built in load center. The combination transfer switch and load center is

pre-wired with a two foot and 30 foot conduit. Circuit

breakers for emergency circuit connections are included.

This UL listed, 2-pole switch is rated at 100 AC amperes at 250 volts maximum. This transfer switch is for indoor use only.

",_ WARNnNG ,_°

_lf this generator is used to power electrical load circuits normally powered by a utility power

source, it is required by code to install a transfer switch. The transfer switch must

effectively isolate the electrical system from the utility distribution system when the generator is operating (NEC 700, 701 & 702). Failure to isolate an electrical system by such means will result in damage to the generator and also may result in injury or death to utility power workers due to backfeed of electrical energy.

If any loss or damage is noted at time of delivery, have the person(s) making the delivery note all damage on the freight bill or affix their signature under the consignor's memo of loss or damage.

If a loss or damage is noted after delivery, separate the damaged materials and contact the Carrier for claim procedures.

"Concealed damage" is understood to mean damage to the contents of a package that is not in evidence at the time of delivery, but is discovered later.

1.2PROTECTION SYSTEMS

Unlike an automobile engine, the generator may have to run for long periods of time with no operator present to monitor engine conditions. For that reason, the engine is equipped with the following systems that protect it against potentially damaging conditions:

There are LED readouts on the control panel to notify personnel that one of these faults has occurred. There is also a "System Set" LED that is lit when all of the conditions describe in Section 1.3 are true.

1.3NEC REQUIREMENT FOR ARC

FAULT CIRCUIT INTERRUPTION

BREAKER FOR BEDROOMS

In 2001, the National Electric Code (NEC) introduced a requirement for new construction. This new requirement indicates the need for Arc Fault Circuit Interrupters to be used to protect the complete branch circuit that feeds a dwelling bedroom. The actual NEC requirement is indicated below.

SECTION 210.12 ARC FAULT CIRCUIT

INTERRUPTER PROTECTION

Definition: An arc fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when an arc fault is detected.

2.Dwelling Unit Bedrooms: All branch circuits that supply 125 volt, single-phase, 15 and 20 ampere outlets installed in dwelling unit bedrooms shall be protected by an arc fault circuit interrupter listed to provide protection of the entire branch circuit.

Section 210.12 requires that AFCl protection be provided on branch circuits that supply outlets (receptacle, lighting, etc.) in dwelling bedrooms. The requirement is limited to 15 and 20 ampere, 125 volt circuits. There is no

prohibition against providing AFCl protection on other circuits or in locations other than bedrooms. Because

circuits are often shared between a bedroom and other areas such as closets and hallways, providing AFCl protection on the complete circuit would comply with 210.12.

If during the installation of the Carrier Home Standby system the decision is made to provide back up power to a bedroom branch circuit, then the circuit breaker in the Carrier Transfer Switch should be replaced with an Arc Fault Circuit Interrupter.

It is most important that breakers only be switched like for like. For instance, if replacing a 15A breaker, it MUST be replaced with a 15A AFCl breaker. Likewise, a 20A breaker MUST be replaced with a 20A AFCl.

These AFCl breakers are available at the nearest electrical wholesaler or hardware store.

Siemens Item #

Description

Q115AF

15A Single Pole AFCl

1.

Low Oil Pressure

Sensor

3.

Overcrank

Q120AF

20A Single Pole AFCl

 

 

2.

High Temperature

Sensor

4.

Overspeed

 

 

4Carrier

Image 6
Contents Air-cooled, Prepackaged Automatic Standby Generators HOW to Obtain Service ContentsOperation and Maintenance IntroductionIntroduction Safetyrules Important Safety Instructions General HazardsImportant Safety Instructions Safetyrules Standards Index12 ARC Fault Circuit Interrupter Protection UNPACKING/INSPECTIONProtection Systems Generator GfciFuel Requirements SpecificationsSystem SET LED GeneratorTransfer Switch Fuel ConsumptionLifting the Generator Battery Installation BatteryAUTO/OFF/MANUAL Auto Position BREAK-IN ProcedureUsing the AUTO/OFF/MANUAL Switch Figure OFF PositionSequence of Automatic Operation 1 12 Vdcaccessory OutletAutomatic Transfer Operation 2 120 VAC Gfci OutletTransfer to Generator Power Source Transfer Back to Utility Power SourceManual Transfer Operation Fuses LOW OIL Pressure SwitchHigh Temperature Switch Over CrankChanging the Engine OIL OIL Change ProcedureChecking the Engine OIL Level Engine OIL RecommendationsSpark Plugs Changing the Engine AIR CleanerChanging the OIL Filter 1 7 KW, 12 Kwand 15 KW GeneratorsBattery Maintenance AUTO/OFF/MANUAL switch is set toReturn to Service OUT of Service ProcedureRemoval from Service Corrosion ProtectionService Schedule ServiceProcedure Frequency Troubleshooting Guide ProblemcausecorrectionWarranty CarrierAir-cooled 7 EW, 12 EW and 15 EW Generators Generac Power SYSTEMS, INC 21 ! Murphy DriveEmission Control System Warranty Emission Related Parts Include the FollowingCatalog NO. OMASPAS07-2

ASPASICCA007, ASPASICCA015, ASPASICCA012 specifications

Carrier, a global leader in heating, ventilating, and air conditioning (HVAC) solutions, has consistently made strides in innovation and efficiency with its range of products. Among its notable offerings are the ASPASICCA012, ASPASICCA015, and ASPASICCA007 air conditioning units. These models exemplify cutting-edge technology, designed to meet diverse cooling needs while prioritizing energy efficiency and user comfort.

The ASPASICCA012 model is tailored for small to medium-sized spaces, providing effective cooling with a capacity of 12,000 BTU. This unit is equipped with advanced inverter technology, allowing it to adjust its compressor speed according to the room's cooling requirements. As a result, it operates more efficiently, consuming less energy while maintaining a stable temperature. Additionally, the ASPASICCA012 features a quiet operation design, making it an ideal choice for bedrooms and offices.

For slightly larger areas, the ASPASICCA015 model offers a cooling capacity of 15,000 BTU. It shares similar technological advancements with the ASPASICCA012, including inverter technology and energy efficiency. However, it can handle higher thermal loads, making it suitable for larger living spaces or commercial applications. The ASPASICCA015 also includes user-friendly controls and smart connectivity options, allowing users to operate the unit remotely via mobile apps.

The ASPASICCA007 is another standout model, aimed at providing an energy-efficient solution for compact spaces with a cooling capacity of 7,000 BTU. It utilizes eco-friendly refrigerants, reducing its carbon footprint while ensuring optimal cooling performance. This model emphasizes quiet operation and includes a sleep mode function that gradually adjusts the temperature to enhance comfort during nighttime.

All three models incorporate features such as a programmable timer, multiple fan speeds, and a self-cleaning function to enhance user experience and maintain air quality. Moreover, Carrier’s commitment to sustainability is evident in each unit’s design, which minimizes energy consumption and leverages environmentally friendly refrigerants.

In summary, the Carrier ASPASICCA series, encompassing models 012, 015, and 007, reflects the company’s dedication to innovation, energy efficiency, and user comfort. Whether it’s a small bedroom or a larger commercial space, these air conditioning units provide reliable cooling solutions tailored to a variety of needs while supporting environmental sustainability.