Briggs & Stratton 30230 manual Generator Storage, Engine Storage, Other Storage Tips

Page 13

STORAGE

5600W Portable Generator

PowerBOSS™

 

 

 

STORAGE

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than

30 days, use the following guidelines to prepare it for storage.

Generator Storage

Clean the generator as outlined in “Generator Cleaning”.

Check that cooling air slots and openings on generator are open and unobstructed.

WARNING

Storage covers can be flammable.

DO NOT place a storage cover over a hot generator.

Let equipment cool for a sufficient time before placing the cover on the equipment.

Engine Storage

See engine operator’s manual for instructions.

Other Storage Tips

To prevent gum from forming in fuel system or on essential carburetor parts, add fuel stabilizer into fuel tank and fill with fresh fuel. Run the unit for several minutes to circulate the additive through the carburetor. The unit and fuel can then be stored for up to

24 months. Fuel stabilizer can be purchased locally.

DO NOT store fuel from one season to another unless it has been treated as described above.

Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it's used with this unit.

Store unit in a clean and dry area.

13

Image 13
Contents Model / Modelo 030230 5600W Safety Rules Table of ContentsEquipment Description When Starting Equipment When Adding or Draining FuelWhen Operating Equipment When Transporting or Repairing EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Carton Contents AssemblyInstall Wheel Kit Unpack the GeneratorBefore Starting the Engine When Adding FuelAdd Engine Oil Add FuelConnecting to a Building’s Electrical System Using the GeneratorSystem Ground Generator LocationOperating Generator Connecting Electrical LoadsStarting the Engine Do not Overload the GENERATOR. See Don’t Overload GeneratorStopping the Engine Receptacles120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptaclesDont Overload Generator Power ManagementCapacity ExampleGeneral Maintenance Recommendations SpecificationsEngine Maintenance Generator MaintenanceGenerator Storage StorageEngine Storage Other Storage TipsProblem Cause Correction TroubleshootingLimited Warranty Tabla DE Contenidos Conserve Estas InstruccionesDescripción DEL Equipo Reglas DE SeguridadCuando Ponga EN Funcionamiento EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Tapa del Depósito del Aceite Llene el motor con aceite Conozca SU GeneradorDesembalaje del Generador MontajeContenido de la Caja Instale el Juego de RuedasAgregar Aceite al Motor Antes DE Darle Arranque AL MotorAgregue Combustible Cuando Añada CombustibleTierra del Sistema USO DEL GeneradorUbicación del Generador Conexión al Sistema Eléctrico de un EdificioEncienda el Motor Operando EL GeneradorConexion De Cargas Electricas No Sobrecargue EL GENERADOR.Vea No Sobrecargue GeneradorParado Del Motor Receptáculos Precaución120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Volt AC, 20 Amp, Receptáculos DoblesCapacidad No Sobrecargue GeneradorControl de la Energía EjemploRecomendaciones Generales DE Mantenimiento EspecificacionesMantenimiento del Motor Para Limpiar el GeneradorAlmacenamiento Diagnositicos DE AveríasAlmacenando el Generador Almacenando el MotorUso comercial Uso del consumidor