Operator Control Panel Continued

WARNING: Never connect this generator to any buildings electrical system unless a licensed electrician has installed an approved transfer switch. The National Electrical Code (NEC) requires that connection of a generator to any electrical circuit normally powered by means of an electric utility must be connected by means of approved transfer switch equipment so as to isolate the electrical circuit from the utility distribution system when the generator is operating. Failure to isolate the electrical circuits by such means may result in injury or death to utility power workers due to backfeed of electrical energy onto the utility lines.

~ AC Output

Two AC receptacles are provided to allow easy connection of electrical loads. Both

 

receptacles may be used at the same time provided the total electrical load does not

 

exceed the generators rated output. GFCI (Ground Fault Circuit Interrupter) provides

 

ground fault protection.

Note: The nominal voltage produced by the generator at each receptacle is 120VAC.

AC Circuit Breaker

Protects the generators output windings from overload (only available on PC1100R).

DC Circuit Breaker

Provide overcurrent protection for the DC Output terminals. When tripped, the plunger

 

will extend from the body of the breaker. Simply push the plunger in to reset the

 

breaker.

DC Output

The DC output can be used to charge automotive type batteries. However several

 

safety precaution must be followed:

SWhen charging a large capacity battery or a totally discharged battery, excessive current may trip the DC breaker. If this happens, use a battery charger to charge the battery. The battery charger can be plugged into the generators AC output.

SAn explosive hydrogen gas is given off by the battery (through the batteries vent holes) when it is charged. Do not allow a spark or open flame to be present during battery charging. Always turn off the generator before disconnecting the battery leads from the DC Output terminals to avoid a spark.

SThe battery contains electrolyte solution which is caustic and can cause severe burns and blindness. If electrolyte contacts skin or eyes, immediately flush the area with water and seek medical attention quickly.

The following precautions are to be followed when working on batteries:

1.Wear full eye protection (safety glasses or goggles) and protective clothing.

2.Where electrolyte contacts the skin, flush the area immediately with water and wash it off using soap and water.

3.Where electrolyte contacts the eyes, immediately flush the eye thoroughly with water and seek medical attention quickly.

4.Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of one pound (500 grams) bicarbonate of soda to one gallon (four liters) of water. the bicarbonate solution is to be added until evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried.

WARNING: A battery presents a risk of electrical shock hazard and high short circuit current. The following precautions are to be followed when working on batteries:

WARNING: The battery electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive. The following precautions are to be followed when working on batteries:

WARNING: A battery presents a risk of fire because they generate hydrogen gas. Hydrogen gas is extremely explosive. Never jump start a battery, smoke in the area around the battery or cause any spark to occur in the area around the battery.

Automotive type batteries can be charged using this output (12VDC @ 8.3 Amperes). Red terminal post is positive (+).

Black terminal post is negative (−).

Note: The DC and AC outlets of the generator can be used at the same time as long as the total power consumed does not exceed the output rating.

4-2 Operation

MN2411

Image 18
Contents PC1100R/PC1700RI Portable Generator California Proposition 65 Warning Table of Contents Ii Table of Contents MN2411 Section Product Safety Information Read This Manual ThoroughlySymbols OperationOperation Warning Statements Burn Installation Maintenance Product Safety Information MN2411 Parts Limited WarrantySection General Information Generator Series LaborGeneral Information MN2411 Section Receiving & Installation StoragePhysical Location Frame Ground Connection Frame Ground Connection Engine OilUse of Electric Motor Loads Section Operation DC Circuit Breaker Operator Control Panel ~ AC OutputAC Circuit Breaker DC OutputRun Engine Switch StopOperator Control Panel DC Circuit Breaker ChokeOperation MN2411 Check Fuel Level Check Oil Level Section Troubleshooting and MaintenanceCheck Air Cleaner Left side cover SE or higher grade SAE 10W−30 or SAE 10W−40Cleaning Clean/Adjust Spark Plug Right side coverClean Spark Arrester Periodic Maintenance ScheduleProblems and Solutions Troubleshooting GuideService Engine Oil SE or higher grade SAE 10W−30 or SAE 10W−40Baldor District Offices California Proposition 65 Warning

PC1700RI, PC1100R specifications

The Baldor PC1100R and PC1700RI are advanced servo motors that stand out in the competitive landscape of industrial automation. These motors are engineered to deliver exceptional performance characterized by high efficiency, reliability, and precision, making them ideal for a variety of applications ranging from robotics to CNC machinery.

The Baldor PC1100R model features a compact design that offers ease of integration into existing systems. With a power rating of 1.1 kW, it delivers robust torque performance while maintaining energy efficiency. This servo motor is equipped with high-resolution encoders that provide precise feedback for accurate position and speed control. The PC1100R also incorporates advanced thermal management technologies to ensure optimal operating temperatures, reducing the risk of overheating and prolonging the motor's lifespan.

On the other hand, the PC1700RI model offers increased power capacity, rated at 1.7 kW. This motor caters to more demanding applications, providing higher torque outputs without compromising on speed and responsiveness. The PC1700RI is designed with a modular architecture, allowing for versatile configurations that can be tailored to specific project needs. Both motors utilize integrated digital controls that enable seamless communication with various automation systems, facilitating smooth operation and enhanced flexibility.

In terms of construction, both the PC1100R and PC1700RI feature durable housing designed to withstand harsh industrial environments. They possess an IP65 rating, making them resistant to dust and water, which is essential for machinery operating in challenging conditions. Additionally, these motors are designed with low vibration and noise levels, contributing to a more comfortable working environment.

Another notable characteristic of the Baldor PC series is the ability to support a variety of feedback devices, including incremental and absolute encoders. This flexibility ensures compatibility with diverse applications and setups. Both models also come with comprehensive support and documentation from Baldor, ensuring users can efficiently implement and maintain their systems.

In summary, the Baldor PC1100R and PC1700RI servo motors exemplify top-tier engineering in the realm of industrial motors. Their features, including compact designs, high efficiency, advanced feedback systems, and robust construction, make them ideal for tackling the demands of modern manufacturing and automation processes. With their reliability and performance, these motors are poised to play a critical role in enhancing productivity across various industries.