Chicago Electric 94678 manual Installation Instructions, General Location, Grounding the Generator

Page 9

10.This Generator provides raw, unregulated output to the battery charging outlet. Incorporating an inline regulator is strongly recommended while charging and the charging process must be monitored at all times. The battery charging output must not be used to power any other device or charge any other type of battery without a proper regulating device.

Installation Instructions

1.Prior to powering tools and equipment, make sure the Generator’s rated watt- age capacity (1000 W) is adequate to supply all electrical loads that the unit will power. If powering exceeds the Generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate Generator.

2.Electrical and other permits may be required for the installation of emergency power systems. Investigate the local building and electrical codes before installing this unit. Installation must be completed by licensed contractors.

GENERAL LOCATION

1.It is recommended to locate and install the Generator outdoors where cooling air is readily available.

2.Install the Generator so that the air inlets and outlets are not blocked by obstruc- tions such as bushes, trees, or snow drifts. Locating it in the path of heavy winds or snowdrifts may require the placement of a barrier for protection. The air inlet, in normal weather conditions, should face the prevailing wind direction.

3.Install the Generator on a concrete slab or other area where rain drainage or flood waters can not reach it.

4.Generator placement should allow four feet of access to all sides for mainte- nance.

5.Place the Generator as close as possible to the electrical tools and equipment be- ing powered to reduce the length of extension cords.

6.If the Generator in located indoors the Engine exhaust must be ventilated to the outdoors using leakproof, heat resistant, flexible, metal, flex tubing.

GROUNDING THE GENERATOR

Note: It is recommended that only a trained and licensed electrician perform this procedure.

Connect a #6 AWG grounding wire (not included) from the Grounding Point (55a) on the Generator to a grounding rod (not included) that has been driven at least 24 inches deep into the earth. The grounding rod must be an earth-driven copper or brass rod (electrode) which can adequately ground the Generator.

SKU 94678

For technical questions, please call 1-800-444-3353.

Page

Image 9
Contents For technical questions or replacement parts, please call HorsepowerUnpacking ContentsSpecifications Save This ManualSKU 94678 For technical questions, please call Electrical Safety General Safety RulesPersonal Safety Work AreaEquipment Use And Care ServiceSpecific Safety Rules Installation Precautions Fire and Explosion PrecautionsKeep the Generator and surrounding area clean at all times Electrical Precautions Mechanical PrecautionsInstallation Instructions General LocationGrounding the Generator Generator Control Illustrations Operation InstructionsPre-start Checks To Power 110/120 Volt AC Tools and Equipment To Charge 12 V Lead-acid Type Batteries See maintenance chart on next Inspection, Maintenance, and CleaningTroubleshooting Maintenance ChartProblem Possible Causes Probable Solutions Part Description ’ty Parts List EngineAssembly Diagram Engine Please Read the Following Carefully Parts List a GeneratorRecord Product’s Serial Number Here Assembly Diagram a GeneratorEmission Control System Warranty Warranted Parts Warranty

94678 specifications

The Chicago Electric 94678 is a versatile and efficient tool that stands out in the realm of power tools, particularly for DIY enthusiasts and professional contractors alike. Primarily known as a 7-inch angle grinder, this robust equipment is engineered to handle a variety of tasks, from grinding and cutting to polishing and sharpening. Its powerful performance and ergonomic design make it a popular choice for both heavy-duty jobs and detailed work.

One of the standout features of the Chicago Electric 94678 is its motor capacity. Equipped with a robust 15-amp motor, this angle grinder delivers substantial power for tackling tough materials, including metal and masonry. The motor provides variable speed options, allowing users to adjust the RPM according to the specific requirements of their tasks. This flexibility in speed control is essential for achieving optimal results, whether one is cutting through thick metal or finely grinding edges.

The durability of the Chicago Electric 94678 is another highlight. Built with a rugged housing and designed to withstand the rigors of demanding work environments, this tool is constructed to last. Additionally, it features a spindle lock that facilitates quick and easy wheel changes, allowing users to switch attachments efficiently without requiring additional tools.

In terms of safety, the angle grinder includes protective features that enhance user safety during operation. The protective guard can be adjusted to accommodate different cutting or grinding tasks, minimizing the risk of debris injury. Moreover, the tool is designed with a comfortable grip and lightweight body, reducing user fatigue during prolonged use.

Another noteworthy characteristic of the Chicago Electric 94678 is its compatibility with various accessories and attachments, making it a multifunctional tool. Users can easily attach different grinding wheels, cut-off blades, and polishing pads to expand its capabilities further, making it suitable for a wide range of applications.

Overall, the Chicago Electric 94678 combines power, efficiency, and versatility, positioning it as an invaluable addition to any workshop. Whether for professional use or personal projects, its features and robust design cater to a diverse array of tasks, ensuring it meets the demands of modern-day users.