Chicago Electric 66603 To Attach the Wheel Assembly, Installation Instructions, See Figure B

Page 11

to the Battery Guard Plate, using two Bolts with Lock Washers (46).

(See Figure B.)

FIGURE B

NEGATIVE BATTERY CABLE

 

12 VDC BATTERY

POSITIVE BATTERY CABLE

(NOT INCLUDED)

 

BATTERY GUARD PLATE (44)

BATTERY BRACKET (47)

 

 

BATTERY TRAY (48)

BOLT WITH LOCK WASHER (46)

 

6.Connect the Engine’s Positive Battery Cable (RED +) to the Battery’s positive (+) terminal. Then connect the Engine’s Negative Battery Cable (BLACK --) to the Battery’s negative (--) terminal. (See Figure B.)

TO ATTACH THE WHEEL ASSEMBLY

1.With additional assistance, and a proper lifting device, raise the left side of the

Generator about 6 to 8 inches off the floor surface.

2.Attach the two Axle Brackets (53) to the lower Frame (42), using two Bolts (52) and two Lock Washer Nuts (13) for each Axle Bracket (See Assy. Diagram).

3.Slide the Axle (49) through the two Axle Brackets (53). (See Assy. Diagram.)

4.Insert one Wheel (50) onto each end of the Axle (49). (See Assy. Diagram.)

5.Secure the Axle (49) and Wheels (50) in place, using four Pins (51).

(See Assy. Diagram.)

INSTALLATION INSTRUCTIONS

1.IMPORTANT: Electrical and other permits may be required for the installation of emergency or portable power systems. Make sure to investigate the local building and electrical codes before installing this unit.

2.Locate the Generator (outdoors only) where cooling air is readily available. Locate the Generator so that the air inlets and outlets are not blocked by obstructions such as bushes, trees, walls, snow drifts, etc. Locating the Generator in the path

SKU 66603

For technical questions, please call 1-800-444-3353.

Page 11

Image 11
Contents Portable Generator For technical questions or replacement parts, please callFor technical questions, please call SpecificationsRead and Understand ALL Instructions General Safety RulesAC Applications Specific Safety Rules ServiceToxic FUMES, FIRE, and Explosion Precautions Electrical Precautions Mechanical PrecautionsChemical Precautions Noise Precaution25’ 50’ 75’ 100’ 150’ MISC. PrecautionSee Figure A, above Control Panel FeaturesUnpacking See Figure C, Battery InstallationSee Figure B To Attach the Wheel AssemblyInstallation Instructions See Assy. DiagramFigure C PRE-START InstructionsFigure F See Figure F This Unit can Power the Following ItemsOperating Instructions See Figure aVolts x Amps = Watts example 120 Volts x 3 Amps = 360 Watts To Connect Electrical LoadsEngine Maintenance INSPECTION, MAINTENANCE, and CleaningGenerator Maintenance Figure H See Figure Please Read the FollowingTroubleshooting Part Description Qty PartsGenerator Assembly Diagram Generator Parts List Engine Record Product’s Serial Number Here Assembly Diagram -ENGINE Wiring Diagram Limited 1 year / 90 Day warranty Emission Control System Warranty Service and Maintenance Emission Control System Warranty