Pentair Quad D.E Section Technical Data, Head Loss Comparison Curves, Flow Rate Table

Page 22

16

Section 8

Technical Data

Head Loss Comparison Curves

QUAD D.E.® CARTRIDGE STYLE FILTER

HEAD LOSS COMPARISON

 

11

 

 

 

 

 

 

 

 

P.S.I.

10

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

LOSS

8

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

PRESSURE

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

FILTER

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

20

30

40

50

60

70

80

90

100 110 120 130 140

BEFORE CLEANABILITY

AFTER CLEANABILITY

FILTER FLOW RATE G.P.M.

Flow Rate Table

QUAD D.E.® CARTRIDGE STYLE FILTER

Recommended Flow Rate

 

 

Filter

Vertical*

Flow Rate GPM

Res. Turnover Capacity (Gallons)

 

 

 

Product #

Model #

Area Sq.

 

 

 

 

 

Clearance

 

 

 

 

 

Res.**

Comm.

6 hours

8 hours

12 hours

 

 

Ft.

 

 

 

 

 

 

 

 

 

 

 

 

188592

Quad 60

60

62"

120

150

43,200

57,600

86,400

 

 

 

 

 

 

 

 

 

188593

Quad 80

80

68"

160

150

57,600

76,800

115,200

 

 

 

 

 

 

 

 

 

188594

Quad 100

100

74"

160

150

57,600

76,800

115,200

 

 

 

 

 

 

 

 

 

NOTE: Actual system flow will depend on plumbing size and other system components.

*Required clearance to remove filter elements.

**Maximum flow rate.

SAVE THESE INSTRUCTIONS

Quad D.E.® Filter Installation and User’s Guide

Image 22
Contents Quad D.E Customer Service Web siteTable of Contents Consumer Information and Safety Important NoticeImportant Safety Precautions General Installation Information Section Introduction Quad D.E. Cartridge Style Filter OverviewGeneral Features Additional FeaturesInstalling the Quad D.E. Filter Section InstallationGeneral Information General Information, cont.’d Section Filter Operation General Filter InformationClamp Installation Section System Restart Instructions System Restart InstructionsPreparing Diatomite Coating the Filter Elements with Diatomaceous EarthSection Maintenance Cleaning the Quad D.E. Filter ManuallyCleaning your Filter using a System with a Separation Tank Replacing Filter Cartridge Style ElementsCleaning Filter Elements Cleaning the Internal Air Bleed Tube Cleaning the High Flow Manual Air Relief Valve Section Troubleshooting Problems and Corrective ActionsTroubleshooting, cont’d Pressure Drops on GaugeSection Replacement Parts Replacement Parts ListHead Loss Comparison Curves Section Technical DataFlow Rate Table QuadD.E 178658 Rev. B 6/4/07