Pentair Section Maintenance, Cleaning the Quad D.E. Filter Manually

Page 15

9

Section 5

Maintenance

Cleaning the Quad D.E.® Filter Manually

1.Turn the pump off, shut off any automatic controls to ensure that the system is not inadvertently started during servicing.

2.Automatic skimmer should have Vari-Flo trimmer valve set to 100% skimmer. This will close off the main drain line. If there is a separate skimmer line and main drain line plumbed to the pump, close the main drain valve.

3.Open the filter High Flow™ manual air relief valve, and the waste drain valve or plug if your system has one. Disconnect air relief valve drain hose if installed.

4.Remove the pump’s hair and lint strainer pot lid and clean the basket. Replace basket and secure lid. Follow the instructions provided with your pump.

5.Never attempt to assemble, disassemble or adjust the filter clamp while there is pressure in the filter. Release the tank clamp assembly and remove tank lid.

6.Ensure the internal air bleed assembly is in place and free of diatomite or debris, see page 12, CLEANING THE INTERNAL AIR BLEED TUBE.

7.Remove top manifold and cartridge style elements separately.

8.Using a garden hose without a nozzle, direct water spray at cartridge style elements to dislodge and wash away accumulated foreign matter. Flush each cartridge inside and out.

WARNING — Please heed all manufacturers' posted instructions, warnings and cautions when using Baquacil® or Baqua Clean®.

NOTE

Special care must be taken when cleaning filter cartridge style elements used in a swimming pool or spa using Baquacil® as a sanitizer. Because of the way Baquacil® works, the filter element must be cleaned more thoroughly and more frequently than in a chlorine system. If extreme care is not taken to completely remove all residue from the filter media a buildup will occur. This buildup will significantly shorten the life of the filter element.

Baquacil® is a mild coagulant which combines bacterial cells as well as other small particles contributed by the environment, bathers, etc. into particles large enough to be trapped by the filter. In comparison with all other trapped contaminants in a typical pool or spa the amount of bacterial cells that are deposited on the filter is minimal. The resulting deposit is a gray sticky film which can only be removed with Baqua Clean®. If TSP or any TSP-type cleaner is used prior to stripping the film, the cleaner and the gray film will combine to form a gum-like substance. Once this occurs, the substance cannot be removed from the media and the filter cartridge must be replaced.

9. Lift bottom manifold out of the tank and flush off any debris.

10.Direct water spray to wash out the inside of the tank body. Water and debris will drain out through the open drain port.

11.Check gasket around outer lip of bottom plate. Gasket must be firmly and evenly set in place. Do not use petroleum base lubricants to avoid damage to the gasket.

12.Place bottom manifold, 4 cartridge style elements, top manifold and air relief tube in place. Make sure the spring and standpipe assembly are retained on the top manifold. Ensure the air relief tube stays in an upright position. This is essential for the maximum air removal from inside the tank.

13.Be certain the o-ring is in position in the lower tank half. Press the filter lid over the lower tank half and sandwich the o-ring in between.

14.Replace tank top and carefully follow instructions on page 6, CLAMP INSTALLATION INSTRUCTIONS.

15.Replace drain plug and reinstall air relief valve drain hose if used.

Quad D.E.® Filter Installation and User’s Guide

Image 15
Contents Quad D.E Web site Customer ServiceTable of Contents Important Notice Consumer Information and SafetyImportant Safety Precautions General Installation Information Quad D.E. Cartridge Style Filter Overview Section IntroductionAdditional Features General FeaturesSection Installation Installing the Quad D.E. FilterGeneral Information General Information, cont.’d General Filter Information Section Filter OperationClamp Installation System Restart Instructions Section System Restart InstructionsCoating the Filter Elements with Diatomaceous Earth Preparing DiatomiteCleaning the Quad D.E. Filter Manually Section MaintenanceReplacing Filter Cartridge Style Elements Cleaning your Filter using a System with a Separation TankCleaning Filter Elements Cleaning the High Flow Manual Air Relief Valve Cleaning the Internal Air Bleed TubeProblems and Corrective Actions Section TroubleshootingPressure Drops on Gauge Troubleshooting, cont’dReplacement Parts List Section Replacement PartsSection Technical Data Head Loss Comparison CurvesFlow Rate Table QuadD.E 178658 Rev. B 6/4/07