Pentair Quad D.E important safety instructions General Installation Information

Page 6

iv

IMPORTANT SAFETY PRECAUTIONS (continued)

General Installation Information

The following information should be read carefully since it outlines the proper manner of care and operation for your filter system. You can expect maximum efficiency and life from your filtration system by following these instructions and taking the necessary preventative care.

Have a trained pool professional perform all pressure tests.

Do not connect the system to a high pressure or city water system.

Trapped air in the system can create a hazardous condition. BE SURE to purge all air from the system before operating or testing equipment.

DO NOT pressure test with compressed air!

Check local codes for restrictions on backwash to waste piping, separation tank requirements and spent D.E. disposal requirements.

DO NOT use more than the recommended amount of D.E. in your filter. To do so can cause a buildup of D.E. and “bridging” between the elements which will plug the filter.

Piping must conform to local/state plumbing and sanitary codes.

Support piping independently to prevent strains on filter or valve.

Fittings restrict flow; for best efficiency, use the fewest possible fittings.

A check valve installed ahead of the filter inlet will prevent contaminants from draining back into the pool.

A check valve installed between the filter and heater will prevent hot water from backing up into the filter and deforming the internal components.

To allow recirculation during precoat, (if precoat pot is used), install a recirculation line with shut-off between pad return line and pump suction.

All wiring, grounding and bonding of associated equipment must meet local and/or National Electrical Code standards.

Quad D.E.® Filter Installation and User’s Guide

Image 6
Contents Quad D.E Customer Service Web siteTable of Contents Consumer Information and Safety Important NoticeImportant Safety Precautions General Installation Information Section Introduction Quad D.E. Cartridge Style Filter OverviewGeneral Features Additional FeaturesSection Installation Installing the Quad D.E. FilterGeneral Information General Information, cont.’d Section Filter Operation General Filter InformationClamp Installation Section System Restart Instructions System Restart InstructionsPreparing Diatomite Coating the Filter Elements with Diatomaceous EarthSection Maintenance Cleaning the Quad D.E. Filter ManuallyCleaning your Filter using a System with a Separation Tank Replacing Filter Cartridge Style ElementsCleaning Filter Elements Cleaning the Internal Air Bleed Tube Cleaning the High Flow Manual Air Relief ValveSection Troubleshooting Problems and Corrective ActionsTroubleshooting, cont’d Pressure Drops on GaugeSection Replacement Parts Replacement Parts ListSection Technical Data Head Loss Comparison CurvesFlow Rate Table QuadD.E 178658 Rev. B 6/4/07