Pentair Quad D.E important safety instructions General Information, cont.’d

Page 10

4

General Information, cont.’d.

7.Make all plumbing connections in accordance with local plumbing and building codes. Check local codes for restrictions on backwash to waste piping, separation tank requirements and spent D.E. disposal requirements.

8.Filter plumbing connections are provided with an o-ring seal. To avoid damage to the o-rings, use only a silicone base lubricant on the o-rings. Do not use pipe joint compound, glue or solvent on the bulkhead connections.

WARNING — THIS FILTER OPERATES UNDER HIGH PRESSURE.

Never subject this filter to pressure in excess of the maximum working pressure - even when conducting hydrostatic pressure tests. Pressures above the maximum working p.s.i. pressure can cause the lid to be blown off, which can result in severe injury, death or property damage.

9.The maximum working pressure of this filter is 50 psi. Never subject this filter to pressure in excess of this amount - even when conducting hydrostatic pressure tests. Pressures above 50 psi can cause the lid to be blown off, which can result in severe injury, death or property damage.

When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing system, ensure that the maximum pressure that the filtration system will be subjected to DOES NOT EXCEED THE MAXIMUM WORKING PRESSURE OF ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM. In most cases, the maximum working pressure will be stated on each component of the system.

If doubt exists as to the pressure to which the system will be subjected, install an ASME approved automatic Pressure Relief or Pressure Regulator in the circulation system for the lowest working pressure of any of the components in the system.

Quad D.E.® Filter Installation and User’s Guide

Image 10
Contents Quad D.E Customer Service Web siteTable of Contents Consumer Information and Safety Important NoticeImportant Safety Precautions General Installation Information Section Introduction Quad D.E. Cartridge Style Filter OverviewGeneral Features Additional FeaturesInstalling the Quad D.E. Filter Section InstallationGeneral Information General Information, cont.’d Section Filter Operation General Filter InformationClamp Installation Section System Restart Instructions System Restart InstructionsPreparing Diatomite Coating the Filter Elements with Diatomaceous EarthSection Maintenance Cleaning the Quad D.E. Filter ManuallyCleaning your Filter using a System with a Separation Tank Replacing Filter Cartridge Style ElementsCleaning Filter Elements Cleaning the Internal Air Bleed Tube Cleaning the High Flow Manual Air Relief ValveSection Troubleshooting Problems and Corrective ActionsTroubleshooting, cont’d Pressure Drops on GaugeSection Replacement Parts Replacement Parts ListHead Loss Comparison Curves Section Technical DataFlow Rate Table QuadD.E 178658 Rev. B 6/4/07