Pentair Section Installation, Installing the Quad D.E. Filter, General Information

Page 9

3

Section 2

Installation

The following general information describes how to install the Quad D.E.® Filter.

Note: Before installing this product, read and follow all warning notices and instructions starting on page ii.

Installing the Quad D.E.® Filter

Only a qualified service person should install the Quad D.E. Filter.

General Information

1.The filter should be mounted on a level concrete slab. Position the filter so that instructions, warnings and the pressure gauge are visible to the operator. It also should be positioned so that the piping connections, control valve and drain port are convenient and accessible for servicing and winterizing.

2.Install electrical controls (e.g., on/off switches, timers, control systems, etc.) at least five (5) feet from the filter. This will allow you enough room to stand clear of the filter during system start up.

3.Allow sufficient clearance around the filter to permit visual verification that the clamp is properly installed around the tank flanges, see Figure 1.

a. Tap the clamp with a mallet or similar tool to ensure uniform loading during clamp tightening.

4.Allow sufficient space above the filter to remove the filter lid for cleaning and servicing. This distance will vary with the model of filter you are using. See Table 1 for the required vertical clearance.

WARNING —Risk of electrical shock or electrocution.

Position the filter and High Flow™ manual air relief valve to safely direct water drainage and purged air or water. Water discharged from an improperly positioned filter or valve can create an electrical hazard that can cause severe personal injury as well as damage property.

5.Position the filter to safely direct water drainage. Rotate the High Flow™ manual air relief valve to safely direct purged air or water. Water discharged from an improperly positioned filter or valve can create an electrical hazard as well as damage property.

CAUTION — The Pentair Quad D.E. filter has a different water flow pattern than all other Pentair D.E. filters. When plumbing the filter with a backwash valve, one of the following valves, listed below, must be used. Failure to use the correct backwash valve could damage the filter elements and void the warranty.

6.Your filter requires one of the following Pentair Water Pool and Spa accessories which must be purchased separately:

a.P/N 261055 - 2” Multiport Valve Kit

b.P/N 261173 - 1½” Multiport Valve Kit

c.P/N 261050 - 2” HiFlow Valve Kit

d.P/N 261165 - 2” PVC Slide Valve Kit

e.P/N 263034 - 2” ABS Slide Valve Kit

 

 

Table 1.

 

 

 

 

 

Vertical

 

Model

P/N

Size

ClearanceReq. NSF

 

 

 

 

 

QUAD60

188592

60 sq. ft.

62 in.

yes

QUAD80

188593

80 sq. ft.

68 in.

yes

QUAD100

188594

100 sq. ft.

74 in.

yes

 

 

 

 

 

Figure 1.

Quad D.E.® Filter Installation and User’s Guide

Image 9
Contents Quad D.E Web site Customer ServiceTable of Contents Important Notice Consumer Information and SafetyImportant Safety Precautions General Installation Information Quad D.E. Cartridge Style Filter Overview Section IntroductionAdditional Features General FeaturesSection Installation Installing the Quad D.E. FilterGeneral Information General Information, cont.’d General Filter Information Section Filter OperationClamp Installation System Restart Instructions Section System Restart InstructionsCoating the Filter Elements with Diatomaceous Earth Preparing DiatomiteCleaning the Quad D.E. Filter Manually Section MaintenanceReplacing Filter Cartridge Style Elements Cleaning your Filter using a System with a Separation TankCleaning Filter Elements Cleaning the High Flow Manual Air Relief Valve Cleaning the Internal Air Bleed TubeProblems and Corrective Actions Section TroubleshootingPressure Drops on Gauge Troubleshooting, cont’dReplacement Parts List Section Replacement PartsSection Technical Data Head Loss Comparison CurvesFlow Rate Table QuadD.E 178658 Rev. B 6/4/07