Meade MAX-ACF instruction manual Hot Button Menus

Page 41

￿Serial Number: Displays the unit's serial number.

Reset: Completely resets Autostar II. Most values entered into the menus revert to factory defaults. Autostar II requires initialization again after a Reset before proceed- ing with observations.

"Hot Button" Menus

Two menus, six object libraries and two functions can be accessed directly using the Number keys (commonly referred to as "hot buttons"). The two functions, the Speed mode and the Utility light are described earlier in the manual.

Focus Control Menus: Press Number key "4" to select these menus directly from Autostar II's keypad. Each time you press Focus, the key toggles between focus/focus speed menus and the preset control menus. When “Focuser: Fast” displays, press the Up or Down Scroll keys to select a focus speed (fast, medium, slow or fine). When “Focuser: Position” displays, use the Up or Down Arrow keys to achieve fine focus of the object.

You can toggle the Focus key to display the “Focuser: Preset” menus. The Focuser preset menu allows you to assign nine focus positions. If you “park” the telescope, you can set your own focus, focus for your observing partners and the focus for your cam- era or imager. Other Preset menus allow you to select a focus you have assigned and also to Sync on a Focus Preset. The Sync on a Focus Preset allows you retrieve focus positions when you do not park your telescope. See page 37 for information about parking your telescope.

Reticle Control Menu: Press Number key "7" to select this menu directly from

Autostar II's keypad. "Reticle Control: Set Intensity" displays. Press ENTER. The Intensity menu allows you to change the intensity of the Reticle Eyepiece Illuminator. Use the Scroll keys to change the value. As you change the value, look through the reticle to note how the Intensity changes.

Note: You may continue to change the values using the Scroll keys (and thus changing the intensity) until you press ENTER again. This allows you to experiment with the intensity level until you decide which intensity level works best for you. This feature operates in the same manner in the Rate and Duty Cycle menus.

When you have finished adjusting the intensity, press ENTER. Press Number key "7" again and the Rate menu displays. Press ENTER again. Use the Scroll keys to change the value of the the rate at which the Reticle Eyepiece blinks. As you change the value, look through the reticle to note how the Blink Rate changes.

When you have finished adjusting the rate, press ENTER. Next, Press Number key "7" again and the Duty Cycle menu displays. Press ENTER again. The Duty Cycle menu controls how long the Reticle Eyepiece Illuminator is on during a blink cycle. Use the Scroll keys to change the value. As you change the value, look through the reticle to note how the Duty Cycle changes. When you have decided on a Duty Cycle value, press ENTER.

To exit the Reticle menu, press MODE once.

Looking at or near the Sun will cause irreversible damage to your eye. Do not point this telescope at or near the

41

Sun. Do not look through the telescope as it is moving.

 

Image 41
Contents MEADE.COM Page Contents Components of MAX Telescope FeaturesPedestal Assembly Pedestal Wedge AssemblyRight Ascension Housing Assembly RA AssemblyDeclination Housing Assembly DEC AssemblyCounterweights COUNTER- WeightsTripod MAX TripodMaleTHE OTA Optical Tube AssemblyControl Panels and Ports RA Assembly Control Panel Saddle Control PanelLibrary # of Objects Autostar II FeaturesTour the Cosmos with Just the Push of a Button Sun. Do not look through the telescope as it is moving Sun. Do not look through the telescope as it is moving Pedestal Assembly and Adjusting Latitude Position Tripod AssemblyIf you need to set for low range or high range Latitude AdjustmentAssembly Requires TWO People to Lift RA AssemblyDEC Saddle Assembly Attach Counterweight Assembly 21 B Attach Optical Tube to the DEC Saddle Attach LOW Latitude CounterweightsWhen end Align the Viewfinder with the OTA Electrical ConnectionsHome Position and Balancing the OTA To Balance the RA AssemblyBalance the DEC Axis This ProcedureAlign the Viewfinder Mounting and Focusing the Viewfinder for the First TimeGetting Started Focusing the Telescope To sync on a focus preset To select a previously defined focus presetSlew Speeds To exit the focus operation at any timeTo prepare your telescope for Automatic Alignment Aligning for the First TimeTest your Collimation How to Drift Align Max Northern HemisphereCollimation OTA align bolt. Misaligned 1, 2, Aligned Follow these steps for collimation of the optical systemParking the Scope Calibrate HomeTo Calculate Sunset time Basic AutostarAutostar II Navigation Exercise Navigating Autostar Example of Locating a menuAutostar IIs Menus To slew the telescope to catalog objects Object MenuUtilities Menu Event MenuGlossary Menu Enter Setup Menu Sun. Do not look through the telescope as it is moving Setup Menu Daylight SAVING, above Hot Button Menus To Edit a Site Adding Observing SitesTo Add a Site to the user-defined site list To GO to a user-entered object Creating User ObjectsIdentify Observing SatellitesDisplayed information Example BrowseInitialize Autostar Alternate Polar AlignmentsTwo-Star Polar Alignment Easy Polar AlignmentUpdate Menu Option Periodic Error CorrectionTrain Menu Option Erase Menu OptionMeade Series 4000 Eyepieces Optional AccessoriesRear cells of Meade Schmidt-Cassegrain models Deep Sky Imager Maintenance Telescope Specifications Meade Consumer Solutions Advanced Autostar II System SpecificationsAutostar II Handbox Specifications Latitude Chart for Major Cities of the World Appendix a Latitude ChartCity State/Prov./Country Latitude City Country LatitudeAppendix B the Moon To observe the Apollo 15 landing site using the Moon optionTraining IntroductionOperation Permanently Mounted Scopes UpdateOther Menus Options Save As and Load OffAppendix D How to Read the Latitude Scale Page Meade Limited Warranty