Intel PCI-X user manual VxWorks usage

Page 36

GigMAC-PMC and PCI

 

GigPMC Switch

Board and Driver Users Manual

10.3DRIVER UTILITY COMMAND REFERENCE 10.3.1 STATISTICS SHOW FUNCTION

vxWorks usage:

inShow(unit)

# unit = device index starting from 0

Linux usage:

./dmUtil –s eth1 # eth1, eth2, etc.

Command output:

in:

unit: 2,

ioAddr: 0xe087c000, intNum: 0x30,

checksum offload: 0, rev: 1.16m

 

link up: 1, full dup: 1,

speed: 1000,

tbiMode: 0

 

 

pci64: 1,

pci66: 1,

pci-x: 0

intrHoldOff: 1

 

 

max frame size: 2048,

numTxBds: 256,

28880

interrupt cnt

 

369621

ints/sec

task cnt

 

369895

timer cnt

311

data timeout cnt

 

311

unclaimed int cnt

0

mgmt int cnt

 

1

RX ERR INTR CNT

0

RX OVRN INT CNT

 

0

RX SEQ INT CNT

0

RX SHRT INT CNT

 

0

RX BUF ERRS

0

RX CKSUM ERRS

 

0

TX ERR INTR CNT

0

TX BUF ERRS

 

0

PCI ERR CNT

0

rx frame cnt

 

1051218

last rx queued

4

max rx queued

 

128

tx frame cnt

1051397

tx short segs

 

0

tx frame segs

1051397

tx cmpl cnt

 

1051227

last tx queued

244

max tx queued

 

244

last tx cmpl

5

max tx cmpl

 

244

max tx segs

1

max tx frm len

 

1500

tx cpy cnt

0

rx byte cnt

 

1576827000

tx byte cnt

1577095500

tot byte cnt

 

3153922500

tot frame cnt

2102615

tot bytes/sec

 

246072000

tot frames/sec

164048

rx alloc errs

 

0

tx alloc errs

0

seq num errs

 

0

bad len cnt

0

rx flow cnt

 

0

bad len size

0

tx flow on cnt

 

8866

tx flow off cnt

8865

tx empty cnt

 

0

rx err bits

00000000

rx extsts bits

 

00000000

tx err bits

00000000

init cnt

 

1

link down int cnt

0

phy reset cnt

 

0

link up int cnt

1

rx reset cnt

 

0

rx start cnt

1

sig det down cnt

 

0

auto neg start cnt

0

sig det up cnt

 

0

auto neg cmpl cnt

0

phy cfg cnt

 

1

phy addr

1

link fail state

 

0

failovr chk cnt

0

recover cnt

 

0

test int req cnt

0

test int rsp cnt

 

0

ints disabled cnt

6707

re-read ints

 

0

num priority queues

1

tx cleanup buf cnt

0

tx loop frames dropped

0

out of buffers

 

0

tx flow ctrld

1

rx flow ctrld

 

0

tmr state

2

data timeout

 

0

bad len val

0

DSS NETWORKS, INC.

Version: 2.6

Page: 36

Image 36
Contents DSS Networks SeptGigMAC-PMC and PCI GigPMC Switch Environmental Specifications Introduction See AlsoCompatibility Model Numbers PMC modelsPCI-Express models PCI-X modelsKEY Features Switch Capabilities Models 5468/6468 OEM Developer KIT ContentsGigMAC-PMC and PCI GigPMC Switch System Requirements Wind RiverHardware Information 6.1 Board Photos DSS NETWORKS, INC Board LED Indicators Link LNK IndicatorTransmit and Receive Activity Indicators Transmit activity Receive activity‰ TBD PMC Connector PIN/SIGNAL Definitions PMC Connectors Pin Assignments Pn1/Jn1 32 Bit PCIPn2/Jn2 32 Bit PCI Pn3/Jn3 32 Bit PCI Pn4/Jn4 optional I/O Model 5468 only PCI Configuration Registers Vendor and Device IDS Eeprom ListingsModel Model 5262-RJ Default Register Settings GigMAC-PMC and PCI GigPMC Switch Power Consumption Specs Hardware InstallationEthernet Frame Latency Installation in PC Computer Embedded or Compact PCI InstallationCopper Cabling and Connector Info Fiber Cable Specifications Copper RJ-45 Connector and Cable Software Driver Installation Linux Driver Installation and UsageBuilding the driver Installing the driver Sample MODULES.CONF File Tuning the Installation ‘Insmod’ Command Line Parameters Parameter Name Valid Default Description Range/SettingsSuggested basic verifications to be run Edit Makefile Un-comment the following define Vxworks Driver Installation and Usage Using dmUtil dpm driver utilityVxWorks usage PCI Registers Show Function MAC Registers Show Function Unit 0, ioAddr 40020000, mac regsMAC Statistics Show Function GigMAC-PMC and PCI GigPMC Switch PHY Registers Show Function Eeprom Show Function MAC Address Show Function Buffer Descriptor Status Show FunctionStarting Frame Generator Stopping Frame GeneratorSwitch Status Show Function DPM Driver Management APIIoctl Command SUB-TYPES Switch Configuration / Management API Functions to reset and initialize switchFunctions to read and write registers in the switch Testing and Verification Specifications Environmental Range Environmental Standards Compliance pendingStandards Compliance GigMAC-PMC and PCI GigPMC Switch Environmental Specifications Technical Support and Warranty Warrantee and Support Info
Related manuals
Manual 406 pages 21.68 Kb