Eiki EZ 250 owner manual Preloaded Eiki Code, Plug and Play SET UP

Page 7

Preloaded Eiki Code

PLUG AND PLAY SET UP

Your EZ-250 system is set to operate right out of the box. It has been pre-configured to work with the current line of EIKI projectors. If you are using one of the projectors listed below simply connect the control cable from the projector to the RS-232c port on the EZ-250 interface. Connect two cat5 cables between the same numbered ports (1 to 1, 2 to 2) on the controller and interface. If you are using a mini-din 8 to DB9 sub cable you must set the dip switches for null modem operation. After you have connected the EZ-250 controller to the EZ-250 interface and the projector, connect the power to the EZ-250 interface.

PRESET CODE The configuration for the following data projectors are preset at the factory:

If you are controlling:

LC-X60, LC-X70, LC-XB15, LC-XB21, LC-XB22, LC-XB26, LC-XB30, LC-SB21

NOTHING FURTHER IS REQUIRED!

The default button configuration is:

 

 

Button 1 On

Button 2 OFF

 

Button 3

Volume Up Button 4 CompositeVid

Button 5 Computer 1

Button 6 Black Screen

Button 7

Volume Down Button 8 S-Video

Button 9 Computer 2

Button 10 Auto Image

The other EIKI standard configurations can still be accessed without disconnecting the system. While the controller is powered up, press button 8 down for 30 seconds (it really takes 30 seconds, please be patient.)After the button

starts to blink, continue pressing the button down. The button will blink once then pause for about 3 seconds then it will blink twice, then pause for 3 seconds, etc. After you have arrived at the proper number, release Button 8. Each set of blinks loads a different set of drivers for EIKI model projectors.

One Blink

LC-X60, LC-X70, LC-XB15, LC-XB21, LC-XB22, LC-XB26, LC-XB30, LC-SB21

Two Blinks

LC-XG110, LC-XG210

Three Blinks LC-SD10, LC-SD20

Four Blinks

LC-X6, LC-SX6, LC-XT3, LC-UXT3

Five Blinks

EIP-200, EIP-1500T, EIP-2500, EIP-3500, EIP-4500

- 3 -

Image 7 Contents
EZ250 Page Table of Contents Iii EZ 250 Parts List Items Provided by Installer Preloaded Eiki Code Plug and Play SET UPPreloaded Timers Connects to EZlink On the hub EZ 250 LayoutEZ 250 software Installation Programming EZ Programming using a Saved fileStandard Programming Reset Button Standard Programming for 2 Devices Standard Programming for a LSE device and a another Device Advanced Programming Selecting Contact Closure Custom Programming Reset Button Timer Programming Labeling Buttons Page Installation of EZ Installing EZ 250 with ONE Device Installing EZ 250 with TWO Devices Installing EZ 250 with another EZ Two EZ 250s Installing EZ 250 with the option Contact closures Installing a EZ 250 with a NPC-1 Page EZ 250 Operational Troubleshooting EZ 250 Software Troubleshooting